ASHEVILLE, NC ·
OSHA Inspection: WEST CAROLINA FREIGHTLINER, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WEST CAROLINA FREIGHTLINER, INC. in 100 HIGHLAND CENTER BOULEVARD, ASHEVILLE, NC 28806 (NAICS 423110). OSHA activity number 309120855.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WEST CAROLINA FREIGHTLINER, INC.
- Site address
- 100 HIGHLAND CENTER BOULEVARD
- City
- ASHEVILLE
- State
- NC
- ZIP
- 28806
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423110
- SIC code (legacy)
- 5012
- Employees
- 12
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
16 citations on file for this inspection.
1910.179 L02 ID
- Issued
- Sep 30, 2005
- Abate by
- Oct 27, 2005
- Penalty
- Initial $188 · Current $188
Recent events (2)
- · A (S) $188.00
- · Z (S) $188.00
95012901
- Issued
- Sep 19, 2005
- Abate by
- Oct 14, 2005
- Penalty
- Initial $188
Recent events (2)
- · I (S)
- · Z (S) $188.00
95012901
- Issued
- Sep 19, 2005
- Abate by
- Oct 14, 2005
- Penalty
- Initial $188
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious harm to employees: a)Facility - - The employer did not ensure that the bottom-running, one-ton Wright-Airway air-powered chain hoist was inspected as required. REFERENCE:ANSI/ASME B30.16 - Overhead Hoist (Underhung): Chapter 16-2 - Inspection, Testing, and Maintenance: Section 16-2.1.1 - Inspection Classification: b)1)Frequent Inspetion: Visual examinations by the operator or other designated person with records not reequired. a)Normal Service: monthly. b)Heavy Service: weekly to monthly. c)Severe Service: daily to weekly. 2)Period Inspection: Visual inspection by a designated person who makes records of external conditions to provide the basis fro a continuing evaluation: a)Normal Service: yearly. b)Heavy Service: semi-annually. c)Severe Service: quarterly. Section 16-2.1.2 - Frequent Inspections: c)2)Hoist upper limit device of electric- or air- powered hoists, without a load on the hook, [shall be inspected] at the beginning or each shift. NOTE:Among other methods, one feasible and acceptable method to correct this hazard is to initiate an inspection procedure for the Wright-Airway chain hoist that insures required inspections of the hoist covering the items listed in B30.16 - Chapter 2 are performed by competent personnel in compliance with the schedules contained in the Chapter.
Recent events (2)
- · I (S)
- · Z (S) $188.00
95012901
- Issued
- Sep 19, 2005
- Abate by
- Oct 14, 2005
- Penalty
- Initial $188
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a)Facility - - The rated load of the Wright-Airway chain hoist was not marked on the hoist or the load block such that the marking was clearly visible from the floor. Reference:ANSI B30.16 - Overhead Hoists (Underhung): Chapter 16-1 - Marking, Construction, and Installation: Section 1.1.1 - Rated Load. The rated load of the hoist shall be marked on the hoist or its load block and shall be legible from the ground or floor. NOTE:Among other methods, one feasible and acceptable method to correct this hazard is to clearly mark the rated load capacity of the hoist on the hoist or its load block so that the load capacity is legible from the floor.
Recent events (2)
- · I (S)
- · Z (S) $188.00
95012901
- Issued
- Sep 19, 2005
- Abate by
- Oct 14, 2005
- Penalty
- Initial $188
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a)Service Department - - The load hook on the Wright-Airway chain hoist did not have a safety latch. REFERENCE:ANSI B30.10 - Hooks: Chapter 1 - Hooks: Section 10-1.2.1.3 - Periodic Inspections: (c) Hooks having any of the following conditions shall be removed from service until repaired or replaced. (5)Inoperative Latch. Any latch that does not close the hook's throat. NOTE:Among other methods, one feasible and acceptable method to correct this hazard is to install a properly sized safety latch on the load hook for the Wright-Airway chain hoist.
Recent events (2)
- · I (S)
- · Z (S) $188.00
1910.305 J02 II
- Issued
- Sep 19, 2005
- Abate by
- Oct 14, 2005
- Penalty
- Initial $263 · Current $263
7F0102
- Issued
- Sep 19, 2005
- Abate by
- Sep 23, 2005
7F0102
- Issued
- Sep 19, 2005
- Abate by
- Oct 14, 2005
1910.22 D01
- Issued
- Sep 19, 2005
- Abate by
- Oct 14, 2005
1910.141 A04 I
- Issued
- Sep 19, 2005
- Abate by
- Oct 14, 2005
1910.157 E03
- Issued
- Sep 19, 2005
- Abate by
- Oct 14, 2005
1910.23 E01
- Issued
- Sep 19, 2005
- Abate by
- Oct 14, 2005
1910.303 B02
- Issued
- Sep 19, 2005
- Abate by
- Oct 14, 2005
1910.303 G02 II
- Issued
- Sep 19, 2005
- Abate by
- Oct 14, 2005
1910.305 B02
- Issued
- Sep 19, 2005
- Abate by
- Oct 14, 2005
1910.305 G01 IIIA
- Issued
- Sep 19, 2005
- Abate by
- Sep 22, 2005
More inspections in this industry (NAICS 423110)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309120855.