Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PROMINENT FRAMING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PROMINENT FRAMING INC. in 150 MAIN STREET, WINTERSVILLE, OH 43953 (NAICS 238130). OSHA activity number 309183929.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Prominent Framing INC. — free Get an email when a new federal OSHA severe-injury report for Prominent Framing INC. is published. One employer, no account, unsubscribe in one click.
Site address
150 MAIN STREET
City
WINTERSVILLE
State
OH
ZIP
43953
Mailing
15109 BARONESS PLACE, LEO, IN 46765
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
SIC code (legacy)
1751
Employees
3
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 5, 2006
Abate by
Jun 15, 2006
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the following:
a.On or about, May 9, 2006, employees engaged in setting 70 foot long wood
trusses on
a new building under construction were exposed to the hazards associated
with truss
collapse due to the lack of inadequate truss bracing.
Among the feasible means of abatement that can be used to correct this are:
Install trusses in accordance with guidance provided by the Wood Truss
Council of
American and Truss Plate Institute, Building Component Safety Information,
BCSI-1-03,
"Guide to Good Practice For Handling, Installing and Bracing of Metal
Plate Connected
Wood Trusses, published Oct 1, 2003, effective Jan 1, 2004 which states:
"Temporary
erection bracing must be applied to three planes of the roof system to
ensure stability:
Plane 1) Top Chord (sheathing), Plane 2) Bottom Chord (ceiling plane), and
Plane 3)
Web Member plane vertical plane perpendicular to trusses."  For trusses
longer than 60
feet, "consult a Registered Professional Engineer to calculate the ground
brace locations
and top chord bracing."

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309183929.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.