WINTERSVILLE, OH —
OSHA Inspection: PROMINENT FRAMING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PROMINENT FRAMING INC. in 150 MAIN STREET, WINTERSVILLE, OH 43953 (NAICS 238130). OSHA activity number 309183929.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROMINENT FRAMING INC.
- Site address
- 150 MAIN STREET
- City
- WINTERSVILLE
- State
- OH
- ZIP
- 43953
- Mailing
- 15109 BARONESS PLACE, LEO, IN 46765
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- SIC code (legacy)
- 1751
- Employees
- 3
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jun 5, 2006
- Abate by
- Jun 15, 2006
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the following: a.On or about, May 9, 2006, employees engaged in setting 70 foot long wood trusses on a new building under construction were exposed to the hazards associated with truss collapse due to the lack of inadequate truss bracing. Among the feasible means of abatement that can be used to correct this are: Install trusses in accordance with guidance provided by the Wood Truss Council of American and Truss Plate Institute, Building Component Safety Information, BCSI-1-03, "Guide to Good Practice For Handling, Installing and Bracing of Metal Plate Connected Wood Trusses, published Oct 1, 2003, effective Jan 1, 2004 which states: "Temporary erection bracing must be applied to three planes of the roof system to ensure stability: Plane 1) Top Chord (sheathing), Plane 2) Bottom Chord (ceiling plane), and Plane 3) Web Member plane vertical plane perpendicular to trusses." For trusses longer than 60 feet, "consult a Registered Professional Engineer to calculate the ground brace locations and top chord bracing."