COCHRANTON, PA —
OSHA Inspection: MEARS TOOL AND DIE, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MEARS TOOL AND DIE, INC. in 24668 ROUTE 322, COCHRANTON, PA 16314 (NAICS 333513). OSHA activity number 309332583.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MEARS TOOL AND DIE, INC.
- Site address
- 24668 ROUTE 322
- City
- COCHRANTON
- State
- PA
- ZIP
- 16314
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333513
- SIC code (legacy)
- 3542
- Employees
- 14
- Ownership type
- A
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 12, 2006
- Abate by
- Jun 6, 2006
- Penalty
- Initial $225 · Current $146 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were potentially exposed to flying plastic shards, plastic projectiles (pipe fragments), and decompressing air because polyvinyl chloride (PVC) plastic pipes and plastic pipe fittings were being used to transport compressed air: A.) Mears Tool & Die, Inc./PVC Piping System/Shop Wide: Compressed air was transported through PVC pipes throughout the shop and was utilized for air wands and machine componets (e.g. EDM wire feeder). ---- The Plastic Pipe Institute's Recommendation B requires PVC piping used for the transport of compressed air to be buried or encased in shatter resistant materials. Furthermore, the manufacturers of PVC plastic pipes and plastic pipe fittings warn against the use of PVC pipes/fittings for the transportation of compressed air. The PVC/pipe fittings manufacturers convey these warnings verbally through sales/personnel distributors, web sites, catalogs, product literature, and on cans of solvent cement. ASME/ANSI B31.8 - Transmission and Distribution Piping Systems Standard prohibits the installation of plastic pipe air line systems above ground except where the above ground portion of the plastic service line is completely enclosing in a conduit or casing of sufficient strength to provide protection from external damage and deterioration. ABATEMENT NOTE: Among other methods, feasible and acceptable means to correct the conditions noted above included the following: Option #1 - Encase the PVC pips and PVC pipe fittings in shatter resistant materials e.g. metal pipes, wooden boxed conduit lined with fiber glass, steel box conduit, etc. Option #2 - Remove the PVC pipes and PVC pipe fittings. Install metal pipe fittings that meet ASTM specifications for transporting compressed air. Option #3 - Remove the PVC Pipes and PVC pipe fittings. Install plastic pipes and pipe fittings that meet ASTM specifications for transporting compressed air. These systems utilize specialized acrylonitrile-butadiene-styrene (ABS) plastic or high density poly ethylene (HDPE) plastic. Plastic pipe and plastic fittings designed for compressed are have a unique color and are coupled with specialized fittings and/or equipment (e.g. fusion). **Note**: DO NOT confuse the ABS utilize in the specialized compressed air systems with ABS-DVW. ABS-DVW is available at most hardware stores and home centers. ABS-DVW is not designed to transport compressed air.
Recent events (2)
- — I (S) $146.00
- — Z (S) $225.00
1910.212 A01
- Issued
- Apr 12, 2006
- Abate by
- Jun 6, 2006
- Penalty
- Initial $300 · Current $195 Reduced
Recent events (2)
- — I (S) $195.00
- — Z (S) $300.00
1910.303 B01
- Issued
- Apr 12, 2006
- Abate by
- Jun 6, 2006
1910.303 B02
- Issued
- Apr 12, 2006
- Abate by
- Jun 6, 2006
- Penalty
- Initial $300 · Current $195 Reduced
Recent events (2)
- — I (S) $195.00
- — Z (S) $300.00
1910.305 G01 III
- Issued
- Apr 12, 2006
- Abate by
- Jun 6, 2006
1910.303 G01 I
- Issued
- Apr 12, 2006
- Abate by
- Jun 6, 2006
1910.303 G02 I
- Issued
- Apr 12, 2006
- Abate by
- Jun 6, 2006
- Penalty
- Initial $300 · Current $195 Reduced
Recent events (2)
- — I (S) $195.00
- — Z (S) $300.00
1910.305 B01
- Issued
- Apr 12, 2006
- Abate by
- Jun 6, 2006
1910.305 B02
- Issued
- Apr 12, 2006
- Abate by
- Jun 6, 2006
More inspections at Mears Tool and DIE, INC.
View Mears Tool and DIE, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333513)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309332583.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.