BROCKWAY, PA —
OSHA Inspection: PROCHEMTECH INTERNATIONAL, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of PROCHEMTECH INTERNATIONAL, INC. in 51 PROCHEMTECH DRIVE, BROCKWAY, PA 15824 (NAICS 334513). OSHA activity number 309333052.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROCHEMTECH INTERNATIONAL, INC.
- Site address
- 51 PROCHEMTECH DRIVE
- City
- BROCKWAY
- State
- PA
- ZIP
- 15824
- Mailing
- PO BOX 214, BROCKWAY, PA 15824
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334513
- SIC code (legacy)
- 3823
- Employees
- 22
- Ownership type
- A
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 18, 2006
- Abate by
- Sep 20, 2006
- Penalty
- Initial $4,900 · Current $2,100 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to explosions from an accumulation of explosive gases, and toxic gases from the uncontrolled release of chlorine gas due to inadequate process hazard evaluations of the mixing process: a.) ProChemTech International Inc., Chemical Batch Plant, High Bay, Reactor #7, PCT 3026 stabilized bromine product - On or about May 18th, 2006, two company employees were mixing a batch of the company's PCT 3026 stabilized bromine product in Reactor #7. During the addition of sodium hypochlorite to a sulfamic acid solution, the unanticipated generation and accumulation of explosive gases caused a detonation type explosion in the reactor. The explosion shattered the reactor lid, which struck employee #1 in the head. The explosion also caused employee #1 to be exposed to an uncontrolled release of chlorine gas which resulted in hospitalization due to chemical burns to the respiratory system. FEASIBLE ABATEMENT METHODS: Among other methods, feasible and acceptable methods to correct the condition include: 1.) Conduct comprehensive process hazard evaluations of the batch processes for the company's chemical products as described in the Center for Chemical Process Safety (CCPS), of the American Institute of Chemical Engineers (AIChE), publication Guidelines for Hazard Evaluation Procedures, Second Edition with Worked Examples, 2.) Develop detailed Standard Operating Procedures (SOPs) for the batch mixing processes. Ensure the SOPs cover start up procedures, normal operating procedures, and emergency shutdown procedures with definitions of abnormal operating conditions requiring emergency shut down, 3.) Conduct thorough reviews of future changes made to batch mixing equipment, procedures, and/or chemicals, 4.) Conduct training with personnel covering the hazards of the chemicals used in the batch processes, process hazard evaluations, and SOPs.
Recent events (2)
- — I (S) $2100.00
- — Z (S) $4900.00
5(a)(1)
- Issued
- Aug 18, 2006
- Abate by
- Sep 20, 2006
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to explosions from an accumulation of explosive gases, and toxic gases from the uncontrolled release of chlorine gas due to an inadequate local exhaust ventilation system for Reactor #7: a.) ProChemTech International Inc., Chemical Batch Plant, High Bay, Reactor #7, PCT 3026 stabilized bromine product - On or about May 18th, 2006, two company employees were mixing a batch of the company's PCT 3026 stabilized bromine product in Reactor #7. During the addition of sodium hypochlorite to a sulfamic acid solution, the unanticipated generation and accumulation of explosive gases was not exhausted properly due to an inadequate local exhaust ventilation system which then resulted in a detonation type explosion in the reactor. The explosion shattered the reactor lid, which struck employee #1 in the head. The explosion also caused employee #1 to be exposed to an uncontrolled release of chlorine gas which resulted in hospitalization due to chemical burns to the respiratory system. FEASIBLE ABATEMENT METHODS: Among other methods, feasible and acceptable methods to correct the condition include: 1.) Following the guidelines established in ANSI/AIHA Z9.2-2001 Fundamentals Governing the Design and Operation of Local Exhaust Ventilation Systems, 2.) Following the guidelines established in NFPA 91 Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Noncombustible Particulate Solids.
5(a)(1)
- Issued
- Aug 18, 2006
- Abate by
- Sep 20, 2006
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to explosions from an accumulation of explosive gases, and toxic gases from the uncontrolled release of chlorine gas due to a lack of effective controls and safe work practices for preventing the generation and discharge of static electricity: a.) ProChemTech International Inc., Chemical Batch Plant, High Bay, Reactor #7, PCT 3026 stabilized bromine product - On or about May 18th, 2006, two company employees were mixing a batch of the company's PCT 3026 stabilized bromine product in Reactor #7. During the addition of sodium hypochlorite to a sulfamic acid solution, explosive gases were generated and accumulated in the reactor. The lack of effective controls and safe work practices for preventing static electricity led to the generation and discharge of static electricity in the reactor, resulting in a detonation type explosion. The explosion shattered the reactor lid, which struck employee #1 in the head. The explosion also caused employee #1 to be exposed to an uncontrolled release of chlorine gas which resulted in hospitalization due to chemical burns to the respiratory system. The ineffective controls and unsafe work practices included, but were not limited to: (1) Bonding and grounding was not utilized for the metal components of the reactor, reactor stand and personnel mezzanine; (2) Liquid and dry chemicals were added to the reactor from the top and were allowed to free fall approximately three to four feet into the reactor; (3) A pH probe and wire were dipped into the solution from the top of the vessel through the man way where chemicals are added; (4) pH reading was taken during addition of chemicals into the reactor rather than allowing an appropriate waiting period to allow built up static charge to dissipate; (5) Personnel were not grounded while taking pH readings in the reactor; (6) Personnel working around the reactor were not using conductive footwear, personal grounding devices, or anti static or conductive clothing; FEASIBLE ABATEMENT METHODS: Among other methods, feasible and acceptable methods to correct the condition include: 1.) Following the guidelines established in NFPA 77 Recommended Practice on Static Electricity.
1910.120 Q01
- Issued
- Aug 18, 2006
- Abate by
- Sep 20, 2006
- Penalty
- Initial $4,200 · Current $2,100 Reduced
Recent events (2)
- — I (S) $2100.00
- — Z (S) $4200.00
1910.120 Q06
- Issued
- Aug 18, 2006
- Abate by
- Sep 20, 2006
1910.134 C01
- Issued
- Aug 18, 2006
- Abate by
- Sep 20, 2006
- Penalty
- Initial $2,100 · Current $1,050 Reduced
Recent events (2)
- — I (S) $1050.00
- — Z (S) $2100.00
1910.134 E01
- Issued
- Aug 18, 2006
- Abate by
- Sep 20, 2006
1910.134 F02
- Issued
- Aug 18, 2006
- Abate by
- Sep 20, 2006
1910.134 K03
- Issued
- Aug 18, 2006
- Abate by
- Sep 20, 2006
1910.307 B
- Issued
- Aug 18, 2006
- Abate by
- Sep 20, 2006
- Penalty
- Initial $4,200 · Current $2,100 Reduced
Recent events (2)
- — I (S) $2100.00
- — Z (S) $4200.00
1910.1200 E01
- Issued
- Aug 18, 2006
- Abate by
- Sep 20, 2006
- Penalty
- Initial $2,100 · Current $1,050 Reduced
Recent events (2)
- — I (S) $1050.00
- — Z (S) $2100.00
1910.1200 H
- Issued
- Aug 18, 2006
- Abate by
- Sep 20, 2006
More inspections at Prochemtech International, INC.
View Prochemtech International, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334513)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309333052.