WARREN, PA ·
OSHA Inspection: PELLEGRINO FOOD PRODUCTS CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PELLEGRINO FOOD PRODUCTS CO., INC. in 100 LOOKOUT STREET, WARREN, PA 16365 (NAICS 311941). OSHA activity number 309336782.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PELLEGRINO FOOD PRODUCTS CO., INC.
- Site address
- 100 LOOKOUT STREET
- City
- WARREN
- State
- PA
- ZIP
- 16365
- Mailing
- P.O. BOX 1606, WARREN, PA 16365
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311941
- SIC code (legacy)
- 2035
- Employees
- 24
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 25, 2007
- Abate by
- Dec 28, 2007
- Penalty
- Initial $1,500 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to an uncontrolled release of anhydrous ammonia: a) Machinery Room - On or about January 29, 2007 at Pellegrino Food Products Co., Inc. employees working in and adjacent to the machinery room were exposed to a potential release of anhydrous ammonia from the refrigeration system used at the facility. Feasible methods of abatement include, but are not limited to the following; 1. Label and identify system piping, valves, and switches. 2. Install entry doors that are tight-fitting, self-closing, and fire-rated equipped with panic-type hardware. 3. Conduct an annual inspection of all anhydrous ammonia system components including vessels and heat exchanger. 4. Close any wall penetrations which would allow refrigerant leakage to other parts of the building. 5. Install self-closing or manual quick-closing emergency stop valves on the oil pot drain. 6. Determine and identify the five (5) year service replacement dates on all pressure relief valves. ABATEMENT NOTE: 1. ANSI/ASHRAE Safety Standard For Refrigeration Systems 15-2004, section 11 General Requirements, paragraph 11.2.2 Controls and Piping Identification - ANSI/ASME A13.1-1996 Scheme For The Identification Of Piping Systems 2. ANSI/IIAR 2-1999 Equipment, Design, and Installation of Ammonia Mechanical Refrigerating Systems, section 6.0 Machinery Room Design, Subsection 6.3 Architectural, Paragraph 6.3.1 Safety, Subparagraph 6.3.1.5 3. IIAR Bulletin No. 110 Guidelines for: Start-UP, Inspection and Maintenance of Ammonia Mechanical Refrigerating Systems, Revised March 2002, Section 6.0 Inspection and Maintenance, Paragraph 6.4 Pressure Vessels and Heat Exchanger 4. ANSI/ASHRAE Safety Standard For Refrigeration Systems 15-2004, section 8 Installation Restrictions, paragraph 8.11 Refrigeration Machinery Room, General Requirements, subparagraph 8.11.2 and 8.11.7 5. ANSI/IIAR 2-1999 Equipment, Design, and Installation of Ammonia Mechanical Refrigerating Systems, section 7.0 Installation, Subsection 7.1.Piping, Paragraph 7.1.2 Item #4 6. IIAR Bulletin No. 110 Guidelines for: Start-UP, Inspection and Maintenance of Ammonia Mechanical Refrigerating Systems, Revised March 2002, Section 6.0 Inspection and Maintenance, Subsection 6.5 Ammonia Pumps, Paragraph 6.5.4 Protection Devices and Subsection 6.6 Valves and Sensing Devices, Paragraph 6.6.3 Pressure Relief Devices
Recent events (2)
- · I (S) $1000.00
- · Z (S) $1500.00
More inspections at Pellegrino Food Products CO., INC.
View Pellegrino Food Products CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311941)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 309336782.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.