OSHA Inspection: NIAGARA CUTTER, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NIAGARA CUTTER, INC. in 150 SOUTH FIFTH STREET, REYNOLDSVILLE, PA 15851 (NAICS 333515). OSHA activity number 309339349.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Niagara Cutter, INC. — free Get an email when a new federal OSHA severe-injury report for Niagara Cutter, INC. is published. One employer, no account, unsubscribe in one click.
Site address
150 SOUTH FIFTH STREET
City
REYNOLDSVILLE
State
PA
ZIP
15851
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333515
SIC code (legacy)
3545
Employees
175
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 1 exposed
Issued
Feb 19, 2008
Abate by
Feb 22, 2008
Penalty
Initial $2,625 · Current $1,840 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to fire and or an explosion:
a) Production Area - An employee operating the Walter CNC machine #1124
was burned
when he opened the front door of the machine to investigate smoke coming
from inside
the machine during a production cycle. A interlock safety device had
failed to secure the
front door in the closed position and allowed it to open slightly which
stopped the flow
of coolant to the part. The part had overheated the coolant causing the
vapor to ignite
when the operator opened the front door resulting in an explosion and fire.
ABATEMENT NOTE:
Reference National Fire Protection Association (NFPA) 79 - Electrical
Standard for
Industrial Machinery, Section 9.3.6 Protective Interlocks
Recent events (2)
  • — I (S) $1840.00
  • — Z (S) $2625.00

1910.1200 F05 I

Serious Gravity 01 1 instance 1 exposed
Issued
Feb 19, 2008
Abate by
Mar 25, 2008
Penalty
Initial $1,125 · Current $785 Reduced
Recent events (2)
  • — I (S) $785.00
  • — Z (S) $1125.00

1910.1200 F05 II

Serious Gravity 01 1 instance 1 exposed
Issued
Feb 19, 2008
Abate by
Mar 25, 2008

View Niagara Cutter, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309339349.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.