UNION CITY, PA —
OSHA Inspection: GENE D. YOST & SON, INC. RIG 236
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GENE D. YOST & SON, INC. RIG 236 in CURTIS 2 UNION TWP ERIE CNTY, UNION CITY, PA 16438 (NAICS 213111). OSHA activity number 309341840.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GENE D. YOST & SON, INC. RIG 236
- Site address
- CURTIS 2 UNION TWP ERIE CNTY
- City
- UNION CITY
- State
- PA
- ZIP
- 16438
- Mailing
- 313 STEELE HILL ROAD, MT. MORRIS, PA 15349
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- SIC code (legacy)
- 1381
- Employees
- 295
- Ownership type
- A
Citations
16 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by and crushing hazards from an oil/gas rig(s) guy wire that were not erected and assembled ("rigged up") in accordance with manufacturer specifications and/or industry standards: a) Erie County, Union Township, PA - On or about June 23, 2008, and at times prior thereto, the Skytop/Brewster Rig #236 commenced well operations without ensuring the rig was erected and assembled ("rigged up") in a safe manner according to manufacturer specifications or industry standards as evidenced by the improper erection, assembly, and installation of guy wires, and anchors: Specifically, these conditions existed on the following components: (1) Rear Crown Guy Wires - The two (2) rear crown guy wires had not been attached and secured to ground anchors. (2) Forward Crown Guy Wires - The two (2) forward crown guy wire ground anchors (steel stakes) were pulled loose from the ground. (3) Derrick Board Guy Wires - The two (2) derrick board guy wires were attached to the pipe tubs approximately 25-feet from the center line. ABATEMENT NOTE: Among others, one feasible and useful abatement method to correct this hazard is to: (1) Follow the requirements of Skytop Rig Co. specification sheet (which replicates the posted placard mounted on the rig provided by the manufacturer) which requires six (6) guy wires from the derrick to be connected to ground anchors. (2) Reference American Petroleum Institute (API) Recommended Practice 54 Paragraph 6.3.2 which states that "Well operations involving the rig shall not be commenced until the rig is rigged up in a safe manner." (3) Reference American Petroleum Institute (API) Recommended Practice Specification 4E Section 3.14 which specifies that the "user shall be responsible for providing anchorage capable of withstanding the maximum guy line loads." (4) OSHA STD 03-12-003 Pub 8-1.8 Guidelines on the Stability of Well Servicing Derricks.
Recent events (2)
- — I (S) $5000.00
- — Z (S) $7000.00
5(a)(1)
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
- Penalty
- Initial $7,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by and crushing hazards from oil/gas rig(s) that was not erected and assembled ("rigged up") in accordance with manufacturer specifications and/or industry standards: a) Erie County, Union Township, PA - On or about June 23, 2008, and at times prior thereto, the Skytop/Brewster Rig #236 commenced well operations without ensuring the rig was erected and assembled ("rigged up") in a safe manner according to manufacturer specifications or industry standards as evidenced by the improper erection, assembly, and installation of anchors: Specifically, these conditions existed on the following components: (1) Anchors - The steel stake anchors were not installed according to any written instructions or pull tested to determined load capacity. (2) Marking of Guy Wires - Visible markers were not placed on each guy wire to prevent accidental contact and resulting physical damage from heavy equipment and vehicle traffic. ABATEMENT NOTE: Among others, one feasible and useful abatement method to correct this hazard is to: (1) Follow the requirements of Skytop Rig Co. specification sheet (which replicates the posted placard mounted on the rig provided by the manufacturer) which requires six (6) guy wires from the derrick to be connected to ground anchors. (2) Reference American Petroleum Institute (API) Recommended Practice 54 Paragraph 6.3.2 which states that "Well operations involving the rig shall not be commenced until the rig is rigged up in a safe manner." (3) Reference American Petroleum Institute (API) Recommended Practice Specification 4E Section 3.14 which specifies that the "user shall be responsible for providing anchorage capable of withstanding the maximum guy line loads." (4) OSHA STD 03-12-003 Pub 8-1.8 Guidelines on the Stability of Well Servicing Derricks. (5) Reference American Petroleum Institute (API) Recommended Practices 4G Section 14.5f states "rig contractor shall be responsible for placing a visible marker on each guy wire".
Recent events (2)
- — I (S)
- — Z (S) $7000.00
5(a)(1)
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
- Penalty
- Initial $7,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by and crushing hazards from an oil/gas rig(s) that was not erected and assembled ("rigged up") in accordance with manufacturer specifications and/or industry standards: a) Erie County, Union Township, PA - On or about June 23, 2008, and at times prior thereto, the Skytop/Brewster Rig #236 commenced well operations without ensuring the rig was erected and assembled ("rigged up") in a safe manner according to manufacturer specifications or industry standards as evidenced by the improper erection, assembly, and installation of rigging equipment: Specifically, these conditions existed on the following components: (1) Rigging Equipment --- Come-Alongs/Chain Around System - A "chain- around" system did not bypass the come-alongs that were used to tension the guy wires. The come-alongs were designed to tension the guy wires and were not designed/installed to transmit the load from the guy wires to the anchors. (2) Rigging Equipment --- Thimbles for Guy Wires - Thimbles were not used on connection points with wire rope and steel chains to prevent crimping and crushing damage to the guy wire anchoring system. ABATEMENT NOTE: Among others, one feasible and useful abatement method to correct this hazard is to: (1) Reference American Petroleum Institute (API) Recommended Practice 54 Paragraph 6.3.2 which states that "Well operations involving the rig shall not be commenced until the rig is rigged up in a safe manner." (2) Reference American Petroleum Institute (API) Recommended Practice Specification 4E Section 3.14 which specifies that the "user shall be responsible for providing anchorage capable of withstanding the maximum guy line loads." (3) OSHA STD 03-12-003 Pub 8-1.8 Guidelines on the Stability of Well Servicing Derricks. (4) J.E. Shaffer Co. "Come-Along" Hand Power Unit. (5) Reference American Petroleum Institute (API) Recommended Practice 9B Section 3.7.4.3 states "apply the second clip as near the loop or thimble as possible...".
Recent events (2)
- — I (S)
- — Z (S) $7000.00
1910.242 A
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
- Penalty
- Initial $5,000 · Current $1,500 Reduced
Recent events (2)
- — I (S) $1500.00
- — Z (S) $5000.00
1910.253 B02 IV
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
- Penalty
- Initial $2,000 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $2000.00
1910.303 B02
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
- Penalty
- Initial $2,000 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $2000.00
1910.305 B01 II
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
1910.305 G02 II
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
- Penalty
- Initial $2,000
Recent events (2)
- — I (S)
- — Z (S) $2000.00
1910.305 G02 III
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
Recent events (2)
- — I (O)
- — Z (S)
1910.1200 G08
- Issued
- Dec 5, 2008
- Abate by
- Dec 10, 2008
- Penalty
- Initial $1,500
Recent events (2)
- — I (O)
- — Z (S) $1500.00
1910.1200 F05 I
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
Recent events (2)
- — I (O)
- — Z (S)
1910.1200 F05 II
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
Recent events (2)
- — I (O)
- — Z (S)
5(a)(1)
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
- Penalty
- Initial $12,500 · Current $12,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees working from an elevated work platform without properly installed emergency escape line and Geronimo device: a) Erie County, Union Township, Curtis #2 Well - On or about June 23, 2008 the Skytop/Brewster Rig #236 emergency escape line for the Geronimo device was improperly anchored in the ground with a steel stake. Employees working from the derrick board were exposed to a fall hazard of fifty five feet (55'). Gene D. Yost & Son, Inc. was previously cited for a violation of this OSH Act standard which was contained in OSHA Inspection Number 309335438, Citation Number 01, Item Number 01, issued on 12/22/06. ABATEMENT REFERENCE: Reference American Petroleum Standard Institute (API) RP 54 Recommended Practice for Occupational Safety of Oil and Gas Well Drilling and Servicing Operations industry standard, section 6.10, Auxiliary Escape and Geronimo Manufacturing Operators Manual, page 6 Ground Anchor
Recent events (2)
- — I (S) $12500.00
- — Z (R) $12500.00
1910.22 C
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
- Penalty
- Initial $25,000 · Current $25,000
Recent events (2)
- — I (S) $25000.00
- — Z (R) $25000.00
1910.23 C01
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
- Penalty
- Initial $20,000 · Current $20,000
1910.151 C
- Issued
- Dec 5, 2008
- Abate by
- Dec 24, 2008
- Penalty
- Initial $1,000
Recent events (2)
- — I (O)
- — Z (O) $1000.00
More inspections in this industry (NAICS 213111)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309341840.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.