DURHAM, NC —
OSHA Inspection: F.D.Y., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of F.D.Y., INC. in 1801 FAYETTEVILLE STREET, DURHAM, NC 27707 (NAICS 722310). OSHA activity number 309413607.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- F.D.Y., INC.
- Site address
- 1801 FAYETTEVILLE STREET
- City
- DURHAM
- State
- NC
- ZIP
- 27707
- Mailing
- 3401 B SAINT VARDELL LANE #B, CHARLOTTE, NC 28217
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 722310
- SIC code (legacy)
- 5812
- Employees
- 365
- Ownership type
- A
Citations
4 citations on file for this inspection.
95012901
- Issued
- Jul 12, 2006
- Abate by
- Jul 17, 2006
- Penalty
- Initial $2,450 · Current $1,715 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical hazards: a)establishment, kitchen meat preparation area - where equipment such as, but not limited to, a Hobart Chopper (model # 841810, Serial # 11253419, 11.1 amps, 115 VAC) was plugged into a receptacle which was not equipped with a Ground Fault Circuit Interrupter (GFCI). Abatement Note: One feasible and acceptable abate method, among others, to correct this hazard is to install Ground Fault Circuit Interrupters. [Reference: National Electrical Code 2005 Edition. NFPA 70, Article 210.9 (B)(2)]
Recent events (2)
- — I (S) $1715.00
- — Z (S) $2450.00
1904.7 B05
- Issued
- Jul 12, 2006
- Abate by
- Jul 17, 2006
- Penalty
- Initial $700
Recent events (2)
- — I (O)
- — Z (O) $700.00
1910.305 G02 III
- Issued
- Jul 12, 2006
- Abate by
- Jul 17, 2006
Recent events (2)
- — I (O)
- — Z (O)
1910.305 J01 IV
- Issued
- Jul 12, 2006
- Abate by
- Jul 17, 2006
Recent events (2)
- — I (O)
- — Z (O)
More inspections in this industry (NAICS 722310)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309413607.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.