MT PROSPECT, IL ·
OSHA Inspection: MARCRES MANUFACTURING, INC. DBA MARCRES METALWERKS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MARCRES MANUFACTURING, INC. DBA MARCRES METALWERKS in 600 CARBOY ROAD, MT PROSPECT, IL 60056 (NAICS 332322). OSHA activity number 309464543.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARCRES MANUFACTURING, INC. DBA MARCRES METALWERKS
- Site address
- 600 CARBOY ROAD
- City
- MT PROSPECT
- State
- IL
- ZIP
- 60056
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- SIC code (legacy)
- 3444
- Employees
- 24
- Ownership type
- Private (A)
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 28, 2005
- Abate by
- Jan 3, 2006
- Penalty
- Initial $375 · Current $263 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) Cutting & Sawing Department, West Wall - The Brobo Super 325 circular cut off saw, used to cut metal, was not equipped with a magnetic restart or similar device. The saw was used last on or about October 24, 2005. (b) Packaging Area, Saw Area, East End - The Rollin vertical band saw, used to cut wood and metal, was not equipped with a magnetic restart or similar device. The saw was used last on or about October 20, 2005. (c) Packaging Area, Saw Area, East End - The Lockformer vertical band saw, used to cut wood and metal, was not equipped with a magnetic restart or similar device. The saw was used last on or about October 20, 2005. Among other methods, one feasible and acceptable method to correct this hazard includes but not limited to the following: Conform to ANSI an American National Standard Institute for Metal Sawing Machines B11.10 - 2003, Section 6.11 in that the machine controls shall incorporate a type of drive motor starter that will disconnect the drive motor from the power source in the event of control voltage or power system failure. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $262.50
- · Z (S) $375.00
1910.178 L04 I
- Issued
- Nov 28, 2005
- Abate by
- Jan 3, 2006
- Penalty
- Initial $300 · Current $210 Reduced
Recent events (2)
- · I (S) $210.00
- · Z (S) $300.00
1910.212 A01
- Issued
- Nov 28, 2005
- Abate by
- Jan 3, 2006
- Penalty
- Initial $375 · Current $263 Reduced
Recent events (2)
- · I (S) $262.50
- · Z (S) $375.00
1910.213 I01
- Issued
- Nov 28, 2005
- Abate by
- Jan 3, 2006
Recent events (2)
- · I (S)
- · Z (S)
1910.212 A03 II
- Issued
- Nov 28, 2005
- Abate by
- Mar 21, 2006
- Penalty
- Initial $1,500 · Current $1,050 Reduced
Recent events (3)
- · P (S) $1050.00
- · I (S) $1050.00
- · Z (S) $1500.00
1910.213 B03
- Issued
- Nov 28, 2005
- Abate by
- Jan 3, 2006
- Penalty
- Initial $375 · Current $263 Reduced
Recent events (2)
- · I (S) $262.50
- · Z (S) $375.00
1910.219 D01
- Issued
- Nov 28, 2005
- Abate by
- Jan 3, 2006
- Penalty
- Initial $375 · Current $263 Reduced
Recent events (2)
- · I (S) $262.50
- · Z (S) $375.00
1910.219 E03 I
- Issued
- Nov 28, 2005
- Abate by
- Jan 3, 2006
Recent events (2)
- · I (S)
- · Z (S)
1910.147 C06 I
- Issued
- Nov 28, 2005
- Abate by
- Jan 3, 2006
Recent events (2)
- · I (O)
- · Z (O)
More inspections at Marcres Manufacturing, INC. DBA Marcres Metalwerks
View Marcres Manufacturing, INC. DBA Marcres Metalwerks's full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 309464543.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.