ARLINGTON HTS, IL ·
OSHA Inspection: J.F. SCHROEDER COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J.F. SCHROEDER COMPANY, INC. in 2616 S. CLEARBROOK DRIVE, ARLINGTON HTS, IL 60005 (NAICS 332116). OSHA activity number 309464600.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J.F. SCHROEDER COMPANY, INC.
- Site address
- 2616 S. CLEARBROOK DRIVE
- City
- ARLINGTON HTS
- State
- IL
- ZIP
- 60005
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332116
- SIC code (legacy)
- 3469
- Employees
- 17
- Ownership type
- Private (A)
Citations
13 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 15, 2005
- Abate by
- Dec 19, 2005
- Penalty
- Initial $750 · Current $375 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to amputation: a) Press Brake Area- On or about October 25, 2005, the Chicago Dreis & Krump power press brake, Serial No. L19265, the foot pedal mechanism used by employees to activate the press brake was not guarded to prevent unintended activation. Employee was exposed to amputation hazards from the point of operation. b) Press Brake Area- On or about October 25, 2005, the Diacro power press brake, Serial No. 6801075124, the foot pedal mechanism used by employees to activate the press brake was not guarded to prevent unintended activation. Employee was exposed to amputation hazards from the point of operation. c) Press Brake Area- On or about October 25, 2005, the Diacro power press brake, Serial No. JA101, the foot pedal mechanism used by employees to activate the press brake was not guarded to prevent unintended activation. Employee was exposed to amputation hazards from the point of operation. Among other methods one feasible and acceptable method to correct this hazard is to include, but not be limited to the following: 1) Conform to the American National Standard Institute B11.3 - 2002, section 6.11.3.1, Safety Requirements for Power Press Brakes. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that the abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $375.00
- · Z (S) $750.00
1910.147 C04 II
- Issued
- Nov 15, 2005
- Abate by
- Jun 1, 2006
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (3)
- · P (S) $375.00
- · I (S) $375.00
- · Z (S) $750.00
1910.147 C05 IID
- Issued
- Nov 15, 2005
- Abate by
- Dec 19, 2005
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $750.00
1910.147 C06 I
- Issued
- Nov 15, 2005
- Abate by
- May 1, 2006
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (3)
- · P (S) $375.00
- · I (S) $375.00
- · Z (S) $750.00
1910.147 C07 I
- Issued
- Nov 15, 2005
- Abate by
- May 1, 2006
Recent events (2)
- · P (S)
- · Z (S)
1910.178 L01 I
- Issued
- Nov 15, 2005
- Abate by
- May 1, 2006
- Penalty
- Initial $600 · Current $300 Reduced
Recent events (3)
- · P (S) $300.00
- · I (S) $300.00
- · Z (S) $600.00
1910.212 A03 II
- Issued
- Nov 15, 2005
- Abate by
- Jun 1, 2006
- Penalty
- Initial $600 · Current $300 Reduced
Recent events (3)
- · P (S) $300.00
- · I (S) $300.00
- · Z (S) $600.00
1910.217 B04 I
- Issued
- Nov 15, 2005
- Abate by
- Dec 19, 2005
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $750.00
1910.217 C02 IA
- Issued
- Nov 15, 2005
- Abate by
- Dec 19, 2005
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $750.00
1910.217 D09 I
- Issued
- Nov 15, 2005
- Abate by
- Dec 19, 2005
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $750.00
1910.217 E01 I
- Issued
- Nov 15, 2005
- Abate by
- Dec 19, 2005
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $750.00
1910.217 E01 II
- Issued
- Nov 15, 2005
- Abate by
- Dec 19, 2005
1910.219 B01
- Issued
- Nov 15, 2005
- Abate by
- Dec 19, 2005
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $750.00
More inspections at J.F. Schroeder Company, INC.
View J.F. Schroeder Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332116)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 309464600.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.