ELKVIEW, WV —
OSHA Inspection: CONTRACTOR SERVICES, INC. OF WEST VIRGINIA
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of CONTRACTOR SERVICES, INC. OF WEST VIRGINIA in V. STEWART WELL #2, ELKVIEW, WV 25071 (NAICS 213111). OSHA activity number 309475655.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONTRACTOR SERVICES, INC. OF WEST VIRGINIA
- Site address
- V. STEWART WELL #2
- City
- ELKVIEW
- State
- WV
- ZIP
- 25071
- Mailing
- 929 CHARLESTON ROAD, SPENCER, WV 25276
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- SIC code (legacy)
- 1381
- Employees
- 9
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 25, 2007
- Abate by
- Jul 2, 2007
- Penalty
- Initial $3,000 · Current $1,650 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were likely to cause death or serious physical harm to the employees in that employees were exposed to thermal burns in the event of a rig fire when working from an elevated work platform without an emergency escape line installed: a.Contractor Services Inc. of West Virginia, V. Stewart Well #2 - Employees were exposed to potential hazards, such as but not limited to, rig collapse, rig fire and thermal burns when working from the monkeyboard/derrick platform while drilling for natural gas. The employer did not install an auxiliary means of escape prior to personnel working up on the derrick, as determined on 05/08/07. NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is to provide an auxiliary means of escape (such as a "Geronimo line") installed on the derrick prior to personnel working in the derrick, as specified by section 6.10.1 of the American Petroleum Institute (API) Standard RP 54 - 1999, "Recommended Practice for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations".
Recent events (2)
- — I (S) $1650.00
- — Z (S) $3000.00
1910.22 C
- Issued
- Jun 25, 2007
- Abate by
- Jul 2, 2007
- Penalty
- Initial $3,000 · Current $1,650 Reduced
Recent events (2)
- — I (R) $1650.00
- — Z (R) $3000.00
More inspections at Contractor Services, INC. of West Virginia
View Contractor Services, INC. of West Virginia's full OSHA safety record →
More inspections in this industry (NAICS 213111)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309475655.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.