OSHA Inspection: STS INTERNATIONAL

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of STS INTERNATIONAL in 429 HALYCON LANE, BERKELEY SPRINGS, WV 25411 (NAICS 334511). OSHA activity number 309476331.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch STS International for free Get an email when a new federal OSHA severe-injury report for STS International is published. One employer, no account, unsubscribe in one click.
Establishment
STS INTERNATIONAL
Site address
429 HALYCON LANE
City
BERKELEY SPRINGS
State
WV
ZIP
25411
Mailing
P O BOX 10, BERKELEY SPRINGS, WV 25411
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334511
SIC code (legacy)
3812
Employees
35
Ownership type
A
Industry flags
Manufacturing safety.

9 citations on file for this inspection.

1910.1200 E01

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Oct 2, 2007
Abate by
Oct 29, 2007
Penalty
Initial $3,000 · Current $3,000
Recent events (2)
  • · F (S) $3000.00
  • · Z (S) $3000.00

1910.1200 G01

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Oct 2, 2007
Abate by
Oct 5, 2007
Recent events (2)
  • · F (S)
  • · Z (S)

1910.1200 H01

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Oct 2, 2007
Abate by
Oct 15, 2007
Recent events (2)
  • · F (S)
  • · Z (S)

1910.157 G01

Serious Gravity 03 1 instance 6 exposed
Issued
Oct 2, 2007
Abate by
Oct 22, 2007
Penalty
Initial $1,500 · Current $1,000 Reduced
Recent events (2)
  • · F (S) $1000.00
  • · Z (S) $1500.00

1910.157 E03

Serious Gravity 03 1 instance 6 exposed
Issued
Oct 2, 2007
Abate by
Oct 15, 2007
Recent events (2)
  • · F (S)
  • · Z (S)

1910.151 B

Serious Gravity 03 1 instance 6 exposed
Issued
Oct 2, 2007
Abate by
Oct 29, 2007
Penalty
Initial $1,500 · Current $1,000 Reduced
Recent events (2)
  • · F (S) $1000.00
  • · Z (S) $1500.00

5(a)(1)

Serious Gravity 10 1 instance 6 exposed
Issued
Oct 2, 2007
Abate by
Oct 15, 2007
Penalty
Initial $3,000 · Current $2,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to the hazards of burns, smoke inhalation, and
death from potential
leakage and ignition of propane from a gas line outlet which was not
capped or plugged
gastight:
a.429 Halycon Lane, Berkeley Springs, WV, Product Test Site, Kitchen Area -
Employees perform work in the kitchen regularly which involves operation of
propane powered stove/oven/grill (American Range).  An unused gas line
outlet adjacent to this stove/oven/grill was not capped or plugged
gastight with
a threaded plug or cap, per NFPA 54 requirements, as observed on 7-25-07.
ABATEMENT NOTE:
Feasible means of abatement for this hazard would be to install a cap or
plug which is
gastight to prevent propane gas from entering the work area through valve
leakage
or
inadvertent opening of the valve.
Recent events (2)
  • · F (S) $2000.00
  • · Z (S) $3000.00

5(a)(1)

Serious Gravity 03 1 instance 6 exposed
Issued
Oct 2, 2007
Abate by
Oct 15, 2007
Penalty
Initial $1,500 · Current $1,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to the hazards of burns, smoke inhalation, and
death due to
malfunction of wet chemical fire suppression unit in ventilation hood due
to lack of regular
inspection and maintenance:
a.429 Halycon Lane, Berkeley Springs, WV, Product Test Site, Kitchen Area -
Employees perform work in the kitchen regularly involving operation of gas
powered stove/oven/grill (American Range), which is provided with a
ventilation hood (Dreaco Products, Inc.) with wet chemical fire suppression
system (Range Guard, Model RG-2.5G).  The employer did not ensure that the
wet chemical fire suppresion system was provided with inspection and
maintenance on a regular basis, per manufacturer and NFPA 17A
requirements, as determined on 7-25-07.
ABATEMENT NOTE:
Feasible means of abatement for this hazard would be to inspect the unit
on a monthly basis
and provide for semiannual maintenance checks, as described by NFPA 17A
requirements
and by the manufacturer.
Recent events (2)
  • · F (S) $1000.00
  • · Z (S) $1500.00

1904.29 B01

Other-than-serious Gravity 00 1 instance 65 exposed
Issued
Oct 2, 2007
Abate by
Oct 22, 2007
Recent events (2)
  • · F (O)
  • · Z (O)

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309476331.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.