BERKELEY SPRINGS, WV ·
OSHA Inspection: STS INTERNATIONAL
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of STS INTERNATIONAL in 429 HALYCON LANE, BERKELEY SPRINGS, WV 25411 (NAICS 334511). OSHA activity number 309476331.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STS INTERNATIONAL
- Site address
- 429 HALYCON LANE
- City
- BERKELEY SPRINGS
- State
- WV
- ZIP
- 25411
- Mailing
- P O BOX 10, BERKELEY SPRINGS, WV 25411
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334511
- SIC code (legacy)
- 3812
- Employees
- 35
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
9 citations on file for this inspection.
1910.1200 E01
- Issued
- Oct 2, 2007
- Abate by
- Oct 29, 2007
- Penalty
- Initial $3,000 · Current $3,000
Recent events (2)
- · F (S) $3000.00
- · Z (S) $3000.00
1910.1200 G01
- Issued
- Oct 2, 2007
- Abate by
- Oct 5, 2007
Recent events (2)
- · F (S)
- · Z (S)
1910.1200 H01
- Issued
- Oct 2, 2007
- Abate by
- Oct 15, 2007
Recent events (2)
- · F (S)
- · Z (S)
1910.157 G01
- Issued
- Oct 2, 2007
- Abate by
- Oct 22, 2007
- Penalty
- Initial $1,500 · Current $1,000 Reduced
Recent events (2)
- · F (S) $1000.00
- · Z (S) $1500.00
1910.157 E03
- Issued
- Oct 2, 2007
- Abate by
- Oct 15, 2007
Recent events (2)
- · F (S)
- · Z (S)
1910.151 B
- Issued
- Oct 2, 2007
- Abate by
- Oct 29, 2007
- Penalty
- Initial $1,500 · Current $1,000 Reduced
Recent events (2)
- · F (S) $1000.00
- · Z (S) $1500.00
5(a)(1)
- Issued
- Oct 2, 2007
- Abate by
- Oct 15, 2007
- Penalty
- Initial $3,000 · Current $2,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of burns, smoke inhalation, and death from potential leakage and ignition of propane from a gas line outlet which was not capped or plugged gastight: a.429 Halycon Lane, Berkeley Springs, WV, Product Test Site, Kitchen Area - Employees perform work in the kitchen regularly which involves operation of propane powered stove/oven/grill (American Range). An unused gas line outlet adjacent to this stove/oven/grill was not capped or plugged gastight with a threaded plug or cap, per NFPA 54 requirements, as observed on 7-25-07. ABATEMENT NOTE: Feasible means of abatement for this hazard would be to install a cap or plug which is gastight to prevent propane gas from entering the work area through valve leakage or inadvertent opening of the valve.
Recent events (2)
- · F (S) $2000.00
- · Z (S) $3000.00
5(a)(1)
- Issued
- Oct 2, 2007
- Abate by
- Oct 15, 2007
- Penalty
- Initial $1,500 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of burns, smoke inhalation, and death due to malfunction of wet chemical fire suppression unit in ventilation hood due to lack of regular inspection and maintenance: a.429 Halycon Lane, Berkeley Springs, WV, Product Test Site, Kitchen Area - Employees perform work in the kitchen regularly involving operation of gas powered stove/oven/grill (American Range), which is provided with a ventilation hood (Dreaco Products, Inc.) with wet chemical fire suppression system (Range Guard, Model RG-2.5G). The employer did not ensure that the wet chemical fire suppresion system was provided with inspection and maintenance on a regular basis, per manufacturer and NFPA 17A requirements, as determined on 7-25-07. ABATEMENT NOTE: Feasible means of abatement for this hazard would be to inspect the unit on a monthly basis and provide for semiannual maintenance checks, as described by NFPA 17A requirements and by the manufacturer.
Recent events (2)
- · F (S) $1000.00
- · Z (S) $1500.00
1904.29 B01
- Issued
- Oct 2, 2007
- Abate by
- Oct 22, 2007
Recent events (2)
- · F (O)
- · Z (O)
More inspections in this industry (NAICS 334511)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309476331.