Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: US AIRWAYS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of US AIRWAYS in LOGAN AIRPORT TERMINAL B, BAGGAGE CLAIM, BOSTON, MA 02128 (NAICS 481111). OSHA activity number 309566016.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch US Airways — free Get an email when a new federal OSHA severe-injury report for US Airways is published. One employer, no account, unsubscribe in one click.
Establishment
US AIRWAYS
Site address
LOGAN AIRPORT TERMINAL B, BAGGAGE CLAIM
City
BOSTON
State
MA
ZIP
02128
Mailing
LOGAN INTERNATIONAL AIRPORT 200 TERMINAL B, BOSTON, MA 02128
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
481111
SIC code (legacy)
4512
Employees
2
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 20, 2006
Abate by
Oct 17, 2006
Penalty
Initial $5,000 · Current $3,750 Reduced
Section 5(a)(1) of the Occupational Safety & Health Act of 1970:  The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees, in
that, employees were
exposed to falls and caught-between hazards from the failure of an
airplane boarding bridge
where the company did not conduct periodic preventive maintenance of the
bridges. The racking
limits had been defeated in that the switch housing mounting bolts had
been loosened. This
condition would have been identified during scheduled preventive
maintenance inspections,
which had not been conducted:
Jobsite: Terminal B, Gate 6.
Employees and passengers were exposed to falls and caught-between hazards
where the
FMC Jetway boarding bridge malfunctioned and collapsed.
One method of abatement, among others, is to implement a preventive
maintenance
program where manufacturer's suggested scheduled inspections would be
conducted by
authorized and competent mechanics.
Recent events (2)
  • — I (S) $3750.00
  • — Z (S) $5000.00

View US Airways's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309566016.