OSHA Inspection: MILLENIUM ELEVATOR GROUP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MILLENIUM ELEVATOR GROUP in 423 OCEAN PARKWAY, BROOKLYN, NY 11218 (NAICS 238290). OSHA activity number 309654465.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Millenium Elevator Group — free Get an email when a new federal OSHA severe-injury report for Millenium Elevator Group is published. One employer, no account, unsubscribe in one click.
Site address
423 OCEAN PARKWAY
City
BROOKLYN
State
NY
ZIP
11218
Mailing
2689 EAST 26TH STREET, BROOKLYN, NY 11235
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238290
SIC code (legacy)
1796
Employees
1
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 11 exposed
Issued
May 9, 2006
Abate by
Jun 26, 2006
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that the
employees were exposed to falling and crushing hazards.
On or about 12/16/05
a)Elevator shaft doors/gate on the 1st floor, 4th floor, and 7th floor.
The elevator shaft doors/gate did not self close.
b)Elevator shaft doors/gate throughout the building.
The elevator car doors/gate were not electronically interlocked to prevent
movement of the elevator when the hoist doors/gate were open.
c)Elevator car.
The elevator car had no walls or roof.
d)Elevator on site.
The elevator was not equipped with a car safety devices..
e)Elevator on site.
The capacity of the elevator was not posted.
ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD, AMONG OTHERS, TO
CORRECT THIS HAZARD IS: to follow ASME A 17.3-1993 Safety Code for Existing
Elevators.
-Section 2.6.2 "Closing of Hoistway Doors" which states that hoistway
doors shall self close.
-Section 2.7.1 "Hoistway Door or Gate Locking Devices" which states that
these gates require
electro-mechanical interlocks to keep them closed when the elevator is
moving, and Section
2.7.4 "Restricted Opening of Hoistway Doors" which states that the
hoistway door shall prevent
the opening of the door when the elevator is not in the landing zone.
-Section 3.4.1 "Car Enclosures" Which states that cars shall be fully
enclosed on all non-
entrance sides and on top.
-Section 3.5.1 "Car Safeties" which states that safeties shall pe provided
to stop the car with its
full rated load from the governor tripping speed.
-Section 3.7.4 "Capacity Plates" Which states that every elevator shall
have a capacity plate.
NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION
AND DOCUMENTATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19NCE

View Millenium Elevator Group's full OSHA safety record →