Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SHAMROCK CABINETS & FIXTURES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SHAMROCK CABINETS & FIXTURES in 10201 EAST 65TH STREET, RAYTOWN, MO 64133 (NAICS 337110). OSHA activity number 309704138.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Shamrock Cabinets & Fixtures — free Get an email when a new federal OSHA severe-injury report for Shamrock Cabinets & Fixtures is published. One employer, no account, unsubscribe in one click.
Site address
10201 EAST 65TH STREET
City
RAYTOWN
State
MO
ZIP
64133
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
SIC code (legacy)
2434
Employees
197
Ownership type
A
Industry flags
Manufacturing safety.

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 1 exposed
Issued
May 26, 2006
Abate by
Jun 8, 2006
Penalty
Initial $1,400 · Current $700 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to struck by hazards of polyvinyl chloride (PVC) plastic pipe
rupturing or
exploding that was used as a pressure air line distribution system
throughout the cabinet finish
area:
(a)On or about March 23, 2006, regular polyvinyl chloride (PVC) pipes were
used
for the transportation of compressed air in the cabinet finish building.
While ultimate responsibility for correcting the hazard rests with the
employer,
given his/her superior knowledge of the work place, feasible and acceptable
methods to correct this hazard among others, include, but are not limited
to:
(1)Install black iron piping for the air distribution system;
(2)Completely enclose all above ground portions of the plastic service in a
shatter resistant conduit or casing of sufficient strength to provide
protection from external damage and deterioration; and
(3)Install approved impact resistant ABS (acrylonitrile-butadiene-styrene)
pipe.
Sections 842.32, 842.43, and 849.52(b) of the American National Standards
Institute /
American Society of Mechanical Engineers (ANSI?ASME B31.8-1986, Gas
Transmission
and Distribution Piping  Systems Standard, limit the operating pressure of
plastic piping
distribution systems to 100 pounds per inch (psi) and prohibit the
installation of such
systems above ground except where  "...the above ground portion of the
plastic service
line is completely enclosed in a conduit or casing sufficient strength to
provide protection
from external damage and deterioration."
Abatement certification is required for this item - use the CERTIFICATION
OF
CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $1400.00

1910.212 A05

Serious Gravity 02 1 instance 1 exposed
Issued
May 26, 2006
Abate by
Jun 7, 2006
Penalty
Initial $1,400 · Current $700 Reduced
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $1400.00

1910.304 A02

Serious Gravity 01 1 instance 1 exposed
Issued
May 26, 2006
Abate by
Jun 6, 2006
Penalty
Initial $1,050 · Current $525 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $1050.00

1910.23 A02

Serious Gravity 02 1 instance 1 exposed
Issued
May 26, 2006
Abate by
Jun 8, 2006
Penalty
Initial $1,400 · Current $700 Reduced
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $1400.00

1910.303 F

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
May 26, 2006
Abate by
Jun 6, 2006
Recent events (2)
  • — I (O)
  • — Z (O)

View Shamrock Cabinets & Fixtures's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309704138.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.