KANSAS CITY, MO —
OSHA Inspection: CHEMCENTRAL CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CHEMCENTRAL CORPORATION in 910 N. PROSPECT AVE., KANSAS CITY, MO 64120 (NAICS 424690). OSHA activity number 309711877.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CHEMCENTRAL CORPORATION
- Site address
- 910 N. PROSPECT AVE.
- City
- KANSAS CITY
- State
- MO
- ZIP
- 64120
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424690
- SIC code (legacy)
- 5169
- Employees
- 14
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 19, 2007
- Abate by
- Aug 21, 2007
- Penalty
- Initial $7,000
B595M250
Recent events (2)
- — F (S)
- — Z (S) $7000.00
1910.106 B02 IIB
- Issued
- Jul 19, 2007
- Abate by
- Aug 21, 2007
259004302460
Recent events (2)
- — F (S)
- — Z (S)
1910.36 D01
- Issued
- Jul 19, 2007
- Abate by
- Aug 21, 2007
- Penalty
- Initial $2,500 · Current $2,500
Recent events (2)
- — F (S) $2500.00
- — Z (S) $2500.00
1910.1200 H03 II
- Issued
- Jul 19, 2007
- Abate by
- Aug 21, 2007
- Penalty
- Initial $7,000
B595M250
Recent events (2)
- — F (S)
- — Z (S) $7000.00
5(a)(1)
- Issued
- Jul 19, 2007
- Abate by
- Aug 21, 2007
- Penalty
- Initial $55,000 · Current $46,188 Reduced
B595M250
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a)In that employees at the distribution facility located at 910 N. Prospect Ave., Kansas City, Missouri, were exposed to the hazard of explosion and fire due to the improper handling and storage of Indopol, a Class III B combustible liquid, that was unstable at elevated temperatures. The Indopol chemical was Polybutene, an Isobutylene/Butene Copolymer which decomposed at elevated temperatures into a flammable atmosphere. The liquid was required to be handled and stored at elevated temperatures due to the product viscosity characteristics. The employer stored two Indopol grades (H-100 and H-300) in the 10,000 gallon compartments of a horizontal, insulated, 20,000 gallon capacity, above ground storage tank. Each tank compartment contained a flanged immersion heater that was operated in order to elevate the temperature of the Indopol to approximately 225 to 250 degrees Fahrenheit so the liquid could be transferred to drums, portable storage tanks, or trailer tanks for shipment to customers. The employer did not heed hazard warnings that were published in the manufacturer's material safety data sheet (MSDS) regarding the unstable properties of Indopol Polybutene when handled and stored at elevated temperatures. Those hazard warnings included, but were not limited to, depolymerization characteristics, requirements for inert gas blanketing during storage, short and long term maximum storage temperatures, and avoidance of ignition conditions. The employer did not heed the warnings published in the MSDS even though the warnings were passed on to customers by the employer via printed and electronic methods. On, or about February 7, 2007, an explosion and fire occurred inside, or in the vicinity of the Indopol tank during, or after employees transferred Indopol H-300 out of tank compartment 41. The explosion and fire resulted in serious injuries to two employees and catastrophic loss of the facility. Among other methods, one feasible and acceptable abatement method to correct this hazard is to undertake the following steps; Follow the Indopol manufacturer's warnings published in the material safety data sheet and the transportation, handling, and storage guide in order to prevent the unstable decomposition of the Polybutene Copolymer to a flammable atmosphere at elevated temperatures and to prevent ignition of any flammable atmosphere that may be generated. Do not store Indopol for prolonged periods of time at temperatures of 60 degrees Celsius (140 degrees Fahrenheit) and above. Exclude oxygen by use of a nitrogen blanket to prevent ignition of a flammable atmosphere in the tank head space. Install a let down pressure regulator and pressure/vacuum valve to maintain tank pressure. Do not use a heating system that may generate localized hot spots at temperatures above 200 degrees Celsius (392 degrees Fahrenheit). Do not store Indopol grades H-100 and H-300 above the recommended maximum storage temperature of 120 degrees Celsius (248 degrees Fahrenheit). Install temperature gauges to determine the temperature of the Indopol. Install a high temperature cut off switch on the flanged immersion heater so the Indopol does not exceed the recommended storage temperature. Operate the flanged immersion heaters in accordance with manufacturer's recommendations. Do not allow the heater to operate when the level of the Indopol is at, or below the heater element tubes. Install a liquid low level indicator, alarm, and automatic heater shutoff for conditions when the level of the Indopol is at the level where the heater shall be shut off. Inspect and maintain the above ground storage tank in accordance with NFPA 30 Flammable and Combustible Liquids Code, 2003 Edition, Section 4.6.7 and Steel Tank Institute SP001-3. Conduct periodic internal inspection and testing of the tank to detect corrosion, cracks, or other defects. Inspect and maintain the flanged immersion heaters in accordance with manufacturer's recommendations that include heater element tube inspection, and heater control testing. Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — F (U) $46187.50
- — Z (W) $55000.00
1910.23 C03
- Issued
- Jul 19, 2007
- Abate by
- Aug 21, 2007
- Penalty
- Initial $55,000 · Current $46,188 Reduced
Recent events (2)
- — F (U) $46187.50
- — Z (W) $55000.00
More inspections at Chemcentral Corporation
View Chemcentral Corporation's full OSHA safety record →
More inspections in this industry (NAICS 424690)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309711877.