Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R KIRK LEONE BUILDERS INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of R KIRK LEONE BUILDERS INC in 4104 BANKS STONE DRIVE, LOT 71, RALEIGH, NC 27603 (NAICS 236115). OSHA activity number 309744464.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R Kirk Leone Builders INC — free Get an email when a new federal OSHA severe-injury report for R Kirk Leone Builders INC is published. One employer, no account, unsubscribe in one click.
Site address
4104 BANKS STONE DRIVE, LOT 71
City
RALEIGH
State
NC
ZIP
27603
Mailing
5832 CARRIAGE FARM DRIVE, RALEIGH, NC 27603
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
SIC code (legacy)
1521
Employees
1
Ownership type
A
Industry flags
Construction safety.

2 citations on file for this inspection.

95012901

Serious 1 instance 8 exposed
Issued
Apr 26, 2006
Abate by
May 1, 2006
Penalty
Initial $350 · Current $245 Reduced
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:  The
employer did not furnish to each of his employees  conditions of
employment and a place of employment free
from recognized hazards that were causing or likely to cause death or
serious physical harm to employees, in
that employees were exposed to electrical hazards as referenced in the
NEC, 305-6(b):
a)4104 Banks Stone Drive, lot 71-a temporary power pole was observed to
have a 240v
outlet with an inoperable GFCI, into which a Emglo compressor was plugged
into and
being accessed by employees of the framing subcontractor.
A feasible means of abatement is to manually check the 120v and 240v side
of the temporary
power pole for a functioning GFCI before plugging any equipment into the
T-pole or allowing
subcontractors to use the T-pole.
Recent events (2)
  • — I (S) $245.00
  • — Z (S) $350.00

1926.20 B02

Serious 1 instance 8 exposed
Issued
Apr 26, 2006
Abate by
May 1, 2006
Penalty
Initial $350 · Current $245 Reduced
Recent events (2)
  • — I (S) $245.00
  • — Z (S) $350.00

View R Kirk Leone Builders INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309744464.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.