OSHA Inspection: S.J.L. WELL SERVICING, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of S.J.L. WELL SERVICING, INC. in KOPF #1-34, SOUTHARD, OK 73770 (NAICS 213112). OSHA activity number 309787109.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S.J.L. Well Servicing, INC. — free Get an email when a new federal OSHA severe-injury report for S.J.L. Well Servicing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
KOPF #1-34
City
SOUTHARD
State
OK
ZIP
73770
Mailing
P.O. BOX 655, HENNESSEY, OK 73742
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
SIC code (legacy)
1389
Employees
4
Ownership type
A
Industry flags
Manufacturing safety.

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 1 exposed
Issued
Oct 26, 2006
Abate by
Nov 13, 2006
Penalty
Initial $625 · Current $625
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm:
Rig #62, Well site Kopf 1-34:  On or about July 27, 2006, employees
working on the derrick
engaged in fishing of an oil and gas well to wash sand out of the casing,
did not have immediate
access to the emergency escape device (geronimo) in the event of an
emergency.  The clevis that
held the emergency escape device to the derrick structure near the finger
board had broke and
the operator of the rig instructed that a piece of rope be used in place
of the clevis.  The rope,
with a knot tied in it, tying the cable to the mast failed to hold the
cable and emergency escape
device (geronimo) in place.  Among feasible and useful methods to correct
the hazard of the
broken clevis would include.
a)Using a substantial, temporary substitute to the original clevis that is
known to
be capable of withstanding 3000 pounds of force, as recommended by the
manufacturer;
b)Conduct on-site repairs using manufacturer's recommended practices to
reattach
the clevis, returning the part of the mast to the manufacturer's original
condition.er's

1910.23 C01

Serious Gravity 01 1 instance 4 exposed
Issued
Oct 26, 2006
Abate by
Oct 31, 2006
Penalty
Initial $375 · Current $375

1910.141 C01 I

Serious Gravity 01 1 instance 4 exposed
Issued
Oct 26, 2006
Abate by
Nov 13, 2006
Penalty
Initial $375 · Current $190 Reduced
Recent events (2)
  • — I (S) $190.00
  • — Z (S) $375.00

1910.141 D02 I

Serious Gravity 01 1 instance 4 exposed
Issued
Oct 26, 2006
Abate by
Nov 13, 2006

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309787109.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.