Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EAGLE ENERGY SERVICES, INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of EAGLE ENERGY SERVICES, INC. in RIG #27, SW1/4 SEC-5N-13 ECM, HOOKER, OK 73945 (NAICS 213112). OSHA activity number 309787133.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eagle Energy Services, INC. — free Get an email when a new federal OSHA severe-injury report for Eagle Energy Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
RIG #27, SW1/4 SEC-5N-13 ECM
City
HOOKER
State
OK
ZIP
73945
Mailing
P.O. BOX 1597, LIBERAL, KS 67905
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
SIC code (legacy)
1389
Employees
6
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 6 exposed
Issued
Sep 19, 2006
Abate by
Sep 25, 2006
Penalty
Initial $2,500 · Current $2,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm:
At the jobsite on or about 07/25/06 employees were required to perform
assigned work using
a Cardwell work over rig without relieving well pressure or operate safely
with the well
under pressure.  Employees were exposed to the type of hazards associated
with serious
burns and lung inhalation.
Among others, one feasible and acceptable method of abatement would be to
comply with the
requirement of American Petroleum Institute's, API Recommended Practice 54,
Recommended Practice for Occupational Safety for Oil and Gas Well Drilling
and Servicing
Operations requirement 6.3.4 and the company's Job Safety Analysis
workbook's
recommended safe practice for bleeding down a well.
Recent events (2)
  • — I (S) $2000.00
  • — Z (S) $2500.00

View Eagle Energy Services, INC.'s full OSHA safety record →