OSHA Inspection: WESTON POWER PLANT

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of WESTON POWER PLANT in 2501 MORRISON AVE, ROTHSCHILD, WI 54474 (NAICS 221122). OSHA activity number 309841799.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Weston Power Plant — free Get an email when a new federal OSHA severe-injury report for Weston Power Plant is published. One employer, no account, unsubscribe in one click.
Establishment
WESTON POWER PLANT
Site address
2501 MORRISON AVE
City
ROTHSCHILD
State
WI
ZIP
54474
Mailing
P.O. BOX 38, ROTHSCHILD, WI 54474
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221122
SIC code (legacy)
4911
Employees
205
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 2 exposed
Issued
Oct 13, 2009
Abate by
Dec 22, 2010
Penalty
Initial $3,150 · Current $3,150
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employmnent and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to the hazard of dust explosions during coal
handling and
processing:
a)Employees remain in an area subject to coal dust dispersion under
pressure during
pulverizer startup.
b)Pulverizers and the associated duct work  are not adequately designed
and constructed
to contain explosion pressures, and the system is not effectively inerted
to prevent an
internal explosion.
c)Pulverizer start up procedures after an unplanned shutdown did not
include means and
methods to assure removal of all fuel sources, e.g., washing out fuel
residue.
Feasible means of abatement include but are not limited to:
*Design, construct, operate and maintain the coal fuel system and facility
according to
the current best practices by established safety, health and construction
standards
including the most recent version of:
*NFPA 68, Venting of Deflagrations
*NFPA 69, Explosion Prevention Systems
*NFPA 85, Boiler and Combustion Systems Hazards Code
*NFPA 850, Recommended Practice for Fire Protection for Electric Generating
Plants and High Voltage Direct Current Converter Stations
*International Mechanical Code, Section 511, Dust Conveying Systems, as
mandated by Wisconsin of Commerce, Chapter  Comm 14.
*Assure appropriate installation and continued maintenance of installed
systems by
company personnel or contractors, including comprehensive training in the
requirements of the referenced standards.
Abatement Certification and Abatement Documentation required.
Recent events (2)
  • — F (S) $3150.00
  • — Z (S) $3150.00

View Weston Power Plant's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309841799.