VEGA BAJA, PR ·
OSHA Inspection: DE ESC REACREDITADA OFELIA DIAZ
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DE ESC REACREDITADA OFELIA DIAZ in URB BRISAS DE TORTUGUERO, VEGA BAJA, PR 00693 (NAICS 611110). OSHA activity number 309855500.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DE ESC REACREDITADA OFELIA DIAZ
- Site address
- URB BRISAS DE TORTUGUERO
- City
- VEGA BAJA
- State
- PR
- ZIP
- 00693
- Mailing
- PO BOX 190759, SAN JUAN, PR 00919
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 611110
- SIC code (legacy)
- 8211
- Employees
- 20
- Ownership type
- State government (C)
Citations
9 citations on file for this inspection.
6A0001
- Issued
- Apr 30, 2010
- Abate by
- May 12, 2010
- Penalty
- Initial $2,625 · Current $2,625
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: At DE Esc. Recreaditada Ofelia Diaz, there were employees performing teaching tasks in trailers used as classrooms. These trailers had a wood ramp and some had loose boards and uneven edges. The trailers were used for the second grade, third grade and special education. The employees were exposed to trip hazards. One feasible and acceptable abatement method among others, to correct this hazard is to replace and secure these boards. En el DE Esc Recreaditada Ofelia Diaz, habian empleados realizando tareas de ensenanza en vagones usados como salones de clases. Estos vagones tenian unas rampas de madera y algunas tenian paneles sueltos y bordes desnivelados. Los vagones eran usados como salones de segundo grado, tercer grado y educacion especial. Los empleados estaban expuestos a tropezones. Un metodo factible y aceptable entre otros, para corregir esta condicion es reemplazar estos paneles y asegurarlos..
6A0001
- Issued
- Apr 30, 2010
- Abate by
- Jun 17, 2010
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: At DE Esc Recreaditada Ofelia Diaz, there were several classrooms like: first grade, second grade, third grade and technology classrooms that were below the terrain level behind the structure. When there was rains the surrounding of the building get flooded for days, even when the rains stopped and the water entered to the classrooms. Some classrooms had crevices on the floor and get flooded through them. One feasible and acceptable abatement method among others, to correct this hazard is performing a structural study of the building to ensure the stability of the structure. En el DE Esc Recreaditada Ofelia Diaz, habian varios salones como: primer grado, segundo grado, tercer grado y tecnologia que se encontraban bajo el nivel del terreno detras de la estructura. Cuando habian lluvias los alrededores del edificio se inundaban por dias, aun cuando las lluvias habian cesado y el agua entraba a los salones. algunos salones tenian grietas en el piso y el agua entraba a traves de ellas. Un metodo viable y aceptable entre otros, para corregir este riesgo era realizar un estudio del edificio para asegurar la estabilidad de la estructura.
1910.22 A01
- Issued
- Apr 30, 2010
- Abate by
- May 19, 2010
- Penalty
- Initial $2,625 · Current $2,625
1910.303 B01
- Issued
- Apr 30, 2010
- Abate by
- May 5, 2010
- Penalty
- Initial $1,500 · Current $1,500
1910.303 B02
- Issued
- Apr 30, 2010
- Abate by
- May 5, 2010
- Penalty
- Initial $1,500 · Current $1,500
1910.22 A03
- Issued
- Apr 30, 2010
- Abate by
- May 26, 2010
- Penalty
- Initial $750 · Current $750
6A0001
- Issued
- Apr 30, 2010
- Abate by
- Jun 17, 2010
- Penalty
- Initial $750 · Current $750
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: At DE Esc Reacreditada Ofelia Diaz, the employees were performing teaching tasks in classroms located in trailers, the employees were exposed to inadequate ventilation. These trailers had air conditioning units. A carbon dioxide measure was taken in the trailer used for Second Grade, there were thirteen students with the teacher inside the trailer. The average measurement was 2722 ppm. The second trailer was used as Special Education Classroom, there were not students at this time. The average for carbon dioxide was 876 ppm. The third classromm was used as Third and Sixth Grade, at the time of the screening there were eighteen students and two teachers inside the trailer. The average measure for carbon dioxide was 2604 ppm. The Niosh recommendations establishes: 600 ppm as minimal air quality complaints and 1,000 ppm as an upper limit to indoor levels. One feasible and acceptable abatement method among others, to correct this hazard is to provide adequate quantities of outside fresh air into the trailers and maintaining a concentration of carbon dioxide between 600 ppm and 1,000 ppm. En el DE Esc Recreaditada Ofelia Diaz, los empleados estaban realizando tareas de ensenanza en los salones localizados en los vagones. Los empleados estaban expuestos a ventilacion inadecuada. Estos salones tenian unidades de aire acondicionado. Una medida de bioxido de carbono fue tomada en el vagon usado como salon para segundo grado, habian trece estudiantes y una maestra al momento de tomar la medida dentro del vagon. La medida promedio para bioxido de carbono era de 2722 ppm. El segundo vagon era usado como salon de educacion especial, al momento de tomar la medida no habian estudiantes en el salon. La medida fue de 876 ppm. El tercer vagon era usado para tercer y sexto grado. Al momento de tomar la medida habian dieciocho estudiantes y dos maestras. La medida promedio de bioxido de carbono fue de 2604 ppm. Las recomendaciones de Niosh establece que 600 ppm como calidad de aire minima y 1000 ppm como limite maximo para niveles interiores. Un metodo viable y aceptable de correccion entre otros, para corregir este riesgo es proveer cantidades adecuadas de aire fresco dentro de los vagones y mantener una concentracion de bioxido de carbono entre 600 ppm a 1,000 ppm.
1904.29 B01
- Issued
- Apr 30, 2010
- Abate by
- May 12, 2010
- Penalty
- Initial $1,000 · Current $1,000
1904.29 B01
- Issued
- Apr 30, 2010
- Abate by
- May 12, 2010
- Penalty
- Initial $1,000 · Current $1,000
More inspections at DE ESC Reacreditada Ofelia Diaz
View DE ESC Reacreditada Ofelia Diaz's full OSHA safety record →
More inspections in this industry (NAICS 611110)
More inspections in PR
Source