Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATENAS GYROS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ATENAS GYROS in CARR 2 KM 84, HATILLO, PR 00659 (NAICS 722212). OSHA activity number 309856144.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atenas Gyros — free Get an email when a new federal OSHA severe-injury report for Atenas Gyros is published. One employer, no account, unsubscribe in one click.
Establishment
ATENAS GYROS
Site address
CARR 2 KM 84
City
HATILLO
State
PR
ZIP
00659
Mailing
PO BOX 9238, ARECIBO, PR 00613
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722212
SIC code (legacy)
5812
Employees
3
Ownership type
A

4 citations on file for this inspection.

6A0001

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
May 7, 2010
Abate by
May 26, 2010
Section 6(a) of the Puerto Rico Occupational Safety and Health Act:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or physical harm to employees in
that employees were
exposed to slips
Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico:
El patrono no
proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten
causando o que
puedan causar muerte o dano fisico a los empleados, por cuanto empleados
estaban expuestos
a resbalones
The employees were exposed to slips and falls. In the room located on the
west side used
as a warehouse were observed in the roof leaks. Among other methods one
feasible and
available method to correct these hazards is to: that the employer seal
the
roof and
cracks.
Los empleados estaban expuestos a resbalones y caidas.  En el salon
localizado en el lado
oeste usado como almacen se observaron filtraciones en el techo. Entre
otros metodos,
un metodo disponible y apropiado para corregir este riesgo es: que el
patrono selle el
techo y las grietas.

6A0001

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
May 7, 2010
Abate by
Jun 3, 2010
Penalty
Initial $150
Section 6(a) of the Puerto Rico Occupational Safety and Health Act:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or physical harm to employees in
that employees were
exposed to fatalities, injuries, and illnesses related to domestic
violence in the workplace
Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico:
El patrono no
proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten
causando o que
puedan causar muerte o dano fisico a los empleados, por cuanto empleados
estaban
expuestos
a fatalidades, lesiones y enfermedades relacionadas a la violencia
domestica en el lugar de
trabajo
The Atenas Gyros did not have a written protocol to handle domestic
violence in the
workplace, as required by the Act for the Implementation of a Protocol to
Handle
Domestic Violence Situations in the Workplace or Place of Employment, Act
No. 217
of 2006. Method to abate the hazard: Develop a written protocol to handle
domestic
violence in the workplace and provide training to all the employees.
Information is
available at the Women's Advocate Office, A Guide for Employers: Domestic
Violence
in the Workplace and other references provided during the inspection.
El patrono Atenas Gyros no tenia un protocolo escrito para manejar la
violencia
domestica en el lugar de trabajo segun lo requerido en la Ley de
Implementacion
del
Protocolo de Manejo Situaciones de Violencia Domestica en el Lugar de
Trabajo o de
Empleo, Ley 217 de 2006. Un metodo para corregir el riesgo: Desarrollar un
protocolo
escrito para manejar la violencia domestica en el lugar de trabajo y
proveer un
adiestramiento a todos los empleados. Informacion se encuentra disponible
en la Oficina
de la Procuradora de Asuntos a la Mujer, Una Guia para Patronos: Violencia
Domestica
en el Lugar de Trabajo y otras referencias provistas durante la
inspeccion.
Recent events (2)
  • — I (O)
  • — Z (O) $150.00

1910.141 D02 III

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
May 7, 2010
Abate by
May 13, 2010

1910.141 D02 IV

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
May 7, 2010
Abate by
May 14, 2010

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309856144.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.