ALLENTOWN, PA —
OSHA Inspection: B. BRAUN MEDICAL
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of B. BRAUN MEDICAL in 901 MARCON BLVD, ALLENTOWN, PA 18109 (NAICS 326199). OSHA activity number 309860492.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- B. BRAUN MEDICAL
- Site address
- 901 MARCON BLVD
- City
- ALLENTOWN
- State
- PA
- ZIP
- 18109
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- SIC code (legacy)
- 3999
- Employees
- 73
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 23, 2006
- Abate by
- Nov 13, 2006
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical hazards due to the lack of frequent inspections of overhead hoist(s): a) Production floor, by machine #58 -- a Budgit one-ton hoist on a Spanco 1-ton gantry frame was plugged into an extension cord; the outer insulation had been pulled from the connector body, on or about 9/26/06. Although periodic inspections are done and written records are maintained, there are no frequent inspections as required. Among other methods, one feasible and accepted method to correct this hazard is to perform frequent inspections as per ANSI B30.16-2.2.1.2: Items such as the following shall be inspected for damage at intervals as defined in 16-2.2.1.1 b.1 (daily to monthly intervals) or as specifically indicated, including observation during operation for any damage which might appear between regular inspections. Deficiencies shall be carefully examined and a determination made as to whether they constitute a safety hazard. a. All controls and operating mechanisms for improper operation; daily. b. All safety devices for malfunction; daily. c. Deterioration or leakage in air systems. d. Hooks for deformations, chemical damage, or cracks. Hooks damaged from chemicals, deformation or cracks opr having more than 15 percent in excess of normal throat opening or more than 10 degree twist from the plane of the unbent hook, refer to paragraph 16-2.2.3.3. c.4. NOTE: Any hook that is twisted or has throat opening in excess of normal, indicates abuse or overloading of the unit. Other load bearing components of the hoise should be inspected for damage; daily. e. Load-carrying ropes or chains. Visual inspection daily for wear, twist, distortion or improper dead-ending to the hoisting drum and other attachments. Check chain also for deposits of foreign material which may be carried into the hoist mechanism. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
1910.242 B
- Issued
- Oct 23, 2006
- Abate by
- Nov 13, 2006
- Penalty
- Initial $1,500 · Current $1,500
1910.1200 H
- Issued
- Oct 23, 2006
- Abate by
- Nov 13, 2006
- Penalty
- Initial $1,500 · Current $1,500
1910.212 A01
- Issued
- Oct 23, 2006
- Abate by
- Nov 28, 2006
- Penalty
- Initial $1,500 · Current $1,500
1910.23 C01
- Issued
- Oct 23, 2006
- Abate by
- Nov 28, 2006
- Penalty
- Initial $1,500 · Current $1,500
1910.37 A03
- Issued
- Oct 23, 2006
- Abate by
- Nov 13, 2006
- Penalty
- Initial $1,125 · Current $1,125
1910.303 G01 II
- Issued
- Oct 23, 2006
- Abate by
- Nov 13, 2006
More inspections at B. Braun Medical
View B. Braun Medical's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309860492.