LAS VEGAS, NV —
OSHA Inspection: ALPHA ELECTRICAL SIGNS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ALPHA ELECTRICAL SIGNS, INC. in 4895 WEST TROPICANA AVENUE, LAS VEGAS, NV 89122 (NAICS 238210). OSHA activity number 309942035.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALPHA ELECTRICAL SIGNS, INC.
- Site address
- 4895 WEST TROPICANA AVENUE
- City
- LAS VEGAS
- State
- NV
- ZIP
- 89122
- Mailing
- 5225 WYNN ROAD, LAS VEGAS, NV 89118
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- SIC code (legacy)
- 1731
- Employees
- 11
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
2 citations on file for this inspection.
618037501
- Issued
- Aug 3, 2006
- Abate by
- Aug 8, 2006
- Penalty
- Initial $375 · Current $375
General-duty citation text
Nevada Revised Statute 618.375(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: Nevada Revised Statute 618.375(1): The employer failed to furnish employment and a place of employment which was free from recognized hazards that were causing or were likely to cause death or serious physical harm to employees: The employer failed to ensure that a vehicle-mounted aerial ladder truck was properly set up as follows: (a)At the parking lot of the work site, an employee was performing electrical installation work from a Wilkie Mfg. LLC aerial ladder mounted to a Ford truck. The employee was sitting on the work platform portion of the ladder at a height of approximately thirteen feet above the parking lot below. (1)The truck was equipped with two outriggers at the rear of the vehicle, only one of which was deployed (on the building side of the truck). The outrigger on the traffic side of the vehicle was not deployed. (2) The wheels of the truck were not chocked to prevent wheel movement. Reference: Wilkie Mfg. LLC Operating Instructions, Parts and Maintenance Manual for Model 540, Serial Number 7754125: Order of Operations Procedure, page 3: -Chock Wheels to prevent wheel movement. -Extend outriggers to firm support surface, outriggers shall be extended until truck chassis is partially supported by outriggers. One feasible means of abatement would be to ensure that the itemslistedintheOrder of Operations Procedure of the Operating Instructions Manual are followed by the operators and users of the vehicle-mounted aerial ladder.
Recent events (2)
- — I (S) $375.00
- — Z (S) $375.00
1926.200 G01
- Issued
- Aug 3, 2006
- Abate by
- Aug 8, 2006
- Penalty
- Initial $375
Recent events (2)
- — I (S)
- — Z (S) $375.00
More inspections at Alpha Electrical Signs, INC.
View Alpha Electrical Signs, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309942035.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.