GRANGEVILLE, ID —
OSHA Inspection: CHS INC. DBA PRIMELAND COOPERATIVES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CHS INC. DBA PRIMELAND COOPERATIVES in 1001 N A ST., GRANGEVILLE, ID 83530 (NAICS 493130). OSHA activity number 309976678.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CHS INC. DBA PRIMELAND COOPERATIVES
- Site address
- 1001 N A ST.
- City
- GRANGEVILLE
- State
- ID
- ZIP
- 83530
- Mailing
- PO BOX 70, GRANGEVILLE, ID 83530
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493130
- SIC code (legacy)
- 4221
- Employees
- 21
- Ownership type
- A
Citations
17 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 26, 2008
- Abate by
- Mar 3, 2008
- Penalty
- Initial $3,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to inhalation hazards of anhydrous ammonia leaks from valves on pressure vessels: (A)Anhydrous Ammonia Storage and Filling Station: On or about October 9, 2007 and at times prior thereto, employees were exposed to unknown concentrations of anhydrous ammonia leaking from valves on the 21,000 gallon pressurized storage tank that had not been repaired. (B)Mobile Anhydrous Ammonia Transportation Equipment: On or about October 5, 2007, employees were exposed to unknown concentrations of anhydrous ammonia leaking from valves on the bandicator that had not been repaired. ABATEMENT NOTE: Amongst other methods, one feasible and acceptable abatement method to correct this hazard is to adhere to the National Board Inspection Code (NBIC) established by The National Board of Boiler and Pressure Vessel Inspectors. Paragraph RB- 6540, Liquid Ammonia Vessels, requires any leak to be thoroughly investigated and the necessary corrective action initiated. In addition, if valves or fittings are in place, check to ensure that these are complete and functional. Note: Abatement certification and documentation required for this item.
Recent events (2)
- — I (S)
- — Z (S) $3500.00
1910.68 E01
- Issued
- Feb 26, 2008
- Abate by
- Mar 21, 2008
- Penalty
- Initial $1,400
Recent events (2)
- — I (S)
- — Z (S) $1400.00
1910.68 E03
- Issued
- Feb 26, 2008
- Abate by
- Mar 21, 2008
Recent events (2)
- — I (S)
- — Z (S)
1910.120 Q01
- Issued
- Feb 26, 2008
- Abate by
- May 15, 2008
- Penalty
- Initial $3,500 · Current $3,500
Recent events (2)
- — I (S) $3500.00
- — Z (S) $3500.00
1910.120 Q03 IV
- Issued
- Feb 26, 2008
- Abate by
- Mar 21, 2008
Recent events (2)
- — I (S)
- — Z (S)
1910.120 Q06
- Issued
- Feb 26, 2008
- Abate by
- Mar 21, 2008
Recent events (2)
- — I (S)
- — Z (S)
1910.120 Q09
- Issued
- Feb 26, 2008
- Abate by
- Mar 21, 2008
Recent events (2)
- — I (S)
- — Z (S)
1910.120 Q10
- Issued
- Feb 26, 2008
- Abate by
- Mar 21, 2008
Recent events (2)
- — I (S)
- — Z (S)
1910.132 A
- Issued
- Feb 26, 2008
- Abate by
- Mar 21, 2008
- Penalty
- Initial $1,400 · Current $1,400
Recent events (2)
- — I (S) $1400.00
- — Z (S) $1400.00
1910.132 D02
- Issued
- Feb 26, 2008
- Abate by
- Mar 21, 2008
Recent events (2)
- — I (S)
- — Z (S)
1910.151 C
- Issued
- Feb 26, 2008
- Abate by
- May 15, 2008
- Penalty
- Initial $1,400 · Current $1,400
Recent events (2)
- — I (S) $1400.00
- — Z (S) $1400.00
1910.272 G01 I
- Issued
- Feb 26, 2008
- Abate by
- Mar 21, 2008
- Penalty
- Initial $1,400
Recent events (2)
- — I (O)
- — Z (S) $1400.00
1910.272 J01
- Issued
- Feb 26, 2008
- Abate by
- May 15, 2008
- Penalty
- Initial $1,750 · Current $1,750
Recent events (2)
- — I (S) $1750.00
- — Z (S) $1750.00
1910.272 J02 II
- Issued
- Feb 26, 2008
- Abate by
- May 15, 2008
Recent events (2)
- — I (S)
- — Z (S)
1910.111 F09
- Issued
- Feb 26, 2008
- Abate by
- Apr 1, 2008
Recent events (2)
- — I (O)
- — Z (O)
1910.272 D
- Issued
- Feb 26, 2008
- Abate by
- May 15, 2008
Recent events (2)
- — I (O)
- — Z (O)
1910.272 K
- Issued
- Feb 26, 2008
- Abate by
- May 15, 2008
Recent events (2)
- — I (O)
- — Z (O)
More inspections at CHS INC. DBA Primeland Cooperatives
View CHS INC. DBA Primeland Cooperatives's full OSHA safety record →
More inspections in this industry (NAICS 493130)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 309976678.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.