JACKSONVILLE, FL —
OSHA Inspection: C.T.T CONSTRUCTION, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of C.T.T CONSTRUCTION, INC. in 7400 WILSON BLVD., JACKSONVILLE, FL 32210 (NAICS 238990). OSHA activity number 310025879.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C.T.T CONSTRUCTION, INC.
- Site address
- 7400 WILSON BLVD.
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32210
- Mailing
- PO BOX 25725, CHARLOTTE, FL 28227
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- SIC code (legacy)
- 1799
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 25, 2006
- Abate by
- Aug 30, 2006
- Penalty
- Initial $600 · Current $360 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards: a.On or about May 5, 2006, at building #2, a job-made wooden ladder used to access the 2nd floor did not have filler blocks tightly installed on the underside of each rung, exposing employees to a 10 feet fall hazard. Among other methods, one feasible and acceptable method to correct this hazard is to follow the American National Standard Institute (ANSI) A14.4-1992 section 4.5.2. ABATEMENT CERTIFICATION IS NOT REQUIREDATION
Recent events (2)
- — I (S) $360.00
- — Z (S) $600.00
1926.25 A
- Issued
- Aug 25, 2006
- Abate by
- Aug 30, 2006
- Penalty
- Initial $600 · Current $360 Reduced
Recent events (2)
- — I (S) $360.00
- — Z (S) $600.00
1926.501 B13
- Issued
- Aug 25, 2006
- Abate by
- Sep 5, 2006
- Penalty
- Initial $750 · Current $450 Reduced
Recent events (2)
- — I (S) $450.00
- — Z (S) $750.00
1926.1053 A03 I
- Issued
- Aug 25, 2006
- Abate by
- Sep 5, 2006
- Penalty
- Initial $600 · Current $360 Reduced
Recent events (2)
- — I (S) $360.00
- — Z (S) $600.00
1926.1053 B01
- Issued
- Aug 25, 2006
- Abate by
- Sep 5, 2006
- Penalty
- Initial $600 · Current $360 Reduced
Recent events (2)
- — I (S) $360.00
- — Z (S) $600.00
More inspections in this industry (NAICS 238990)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310025879.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.