OSHA Inspection: SODEXHO, INC. D.B.A. SDH EDUCATION EAST, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SODEXHO, INC. D.B.A. SDH EDUCATION EAST, LLC in 1801 FAYETTEVILLE STREET, DURHAM, NC 27707 (NAICS 722310). OSHA activity number 310038757.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sodexho, INC. D.B.A. SDH Education East, LLC — free Get an email when a new federal OSHA severe-injury report for Sodexho, INC. D.B.A. SDH Education East, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1801 FAYETTEVILLE STREET
City
DURHAM
State
NC
ZIP
27707
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722310
SIC code (legacy)
5812
Employees
95762
Ownership type
A

3 citations on file for this inspection.

95012901

Serious 1 instance 1 exposed
Issued
Jul 25, 2006
Abate by
Jul 28, 2006
Penalty
Initial $2,450 · Current $1,715 Reduced
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:  The
employer did not furnish to each of his employees  conditions of
employment and a place of employment free
from recognized hazards that were causing or likely to cause death or
serious physical harm to employees, in
that employees were exposed to electrical hazards.
a)establishment, kitchen meat preparation area - where equipment such as,
but not limited to, a
Hobart Chopper(model # 841810, serial # 11253419, 11.1 amps, 115 VAC) was
plugged into a
receptacle which was not equipped with a Ground Fault Circuit Interrupter
(GFCI).
Abatement Note:
One feasible and acceptable abate method, among others, to correct this
hazard is to install Ground
Fault Circuit Interrupters.
[Reference:  National Electrical Code 2005 Edition. NFPA 70, Article 210.9
(B)(2)]
Recent events (2)
  • — I (S) $1715.00
  • — Z (S) $2450.00

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Jul 25, 2006
Abate by
Jul 28, 2006
Recent events (2)
  • — I (O)
  • — Z (O)

1910.305 J01 IV

Other-than-serious 1 instance 1 exposed
Issued
Jul 25, 2006
Abate by
Jul 28, 2006
Recent events (2)
  • — I (O)
  • — Z (O)

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310038757.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.