GREENVILLE, NC —
OSHA Inspection: CALDWELL DESIGN & FABRICATION, LLC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CALDWELL DESIGN & FABRICATION, LLC. in 801 STATON RD., GREENVILLE, NC 27834 (NAICS 336612). OSHA activity number 310042841.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CALDWELL DESIGN & FABRICATION, LLC.
- Site address
- 801 STATON RD.
- City
- GREENVILLE
- State
- NC
- ZIP
- 27834
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336612
- SIC code (legacy)
- 3732
- Employees
- 50
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
20 citations on file for this inspection.
1910.106 E02 IIB2
- Issued
- Sep 6, 2006
- Abate by
- Sep 11, 2006
- Penalty
- Initial $1,500 · Current $1,000 Reduced
Recent events (2)
- — I (R) $1000.00
- — Z (R) $1500.00
1910.106 E02 IVA
- Issued
- Sep 6, 2006
- Abate by
- Sep 11, 2006
Recent events (2)
- — I (R)
- — Z (R)
1910.107 B05 IV
- Issued
- Sep 6, 2006
- Abate by
- Sep 11, 2006
- Penalty
- Initial $1,500 · Current $1,000 Reduced
Recent events (2)
- — I (R) $1000.00
- — Z (R) $1500.00
1910.107 E02
- Issued
- Sep 6, 2006
- Abate by
- Sep 11, 2006
Recent events (2)
- — I (R)
- — Z (R)
1910.307 B
- Issued
- Sep 6, 2006
- Abate by
- Sep 11, 2006
Recent events (2)
- — I (R)
- — Z (R)
1910.133 A03
- Issued
- Sep 6, 2006
- Abate by
- Oct 2, 2006
- Penalty
- Initial $100 · Current $100
Recent events (2)
- — I (R) $100.00
- — Z (R) $100.00
1910.134 C02 II
- Issued
- Sep 6, 2006
- Abate by
- Oct 24, 2006
- Penalty
- Initial $100 · Current $100
Recent events (2)
- — I (R) $100.00
- — Z (R) $100.00
1910.303 B02
- Issued
- Sep 6, 2006
- Abate by
- Oct 2, 2006
- Penalty
- Initial $100 · Current $100
Recent events (2)
- — I (R) $100.00
- — Z (R) $100.00
1910.305 G01 IIIA
- Issued
- Sep 6, 2006
- Abate by
- Oct 2, 2006
- Penalty
- Initial $100 · Current $100
Recent events (2)
- — I (R) $100.00
- — Z (R) $100.00
1910.1200 F05 II
- Issued
- Sep 6, 2006
- Abate by
- Sep 11, 2006
- Penalty
- Initial $100 · Current $100
Recent events (2)
- — I (R) $100.00
- — Z (R) $100.00
95012901
- Issued
- Sep 6, 2006
- Abate by
- Sep 11, 2006
- Penalty
- Initial $225 · Current $100 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a)facility - where employees were allowed to use including, but not limited to, a Barrington hook-type underhung 2 ton hoist that was used to lift hard tops (approximately 400-500 lbs) that was missing its hook latch. The hoist was not inspected in the past 12 months. One feasible and acceptable abatement method, among others, to correct this hazard is to replace the missing latch and conduct inspections of the hoist. b)facility - where employees were allowed to use including, but not limited to, a Barrington hook-type underhung 2 ton hoist that was used to lift hard tops (approximately 400-500 lbs) where the structure supporting the hoist and weight of the lift was not load rated to determine its load capacity. One feasible and acceptable abatement method, among others, to correct this hazard is to determine load rating of the support beams and label the beam with the load rating. References: Reference ANSI B30.16-1981, Section 16-2.1.3: Periodic Inspection, Complete inspections of the hoist shall be performed at intervals as defined in 16-2.1.1(b)(2) & Reference ANSI B30.16-1981, Section 16-2.2.2: Load Test shall be performed as outlined in 16-2.2.2
Recent events (2)
- — I (S) $100.00
- — Z (S) $225.00
1910.23 C01
- Issued
- Sep 6, 2006
- Abate by
- Sep 11, 2006
- Penalty
- Initial $375 · Current $200 Reduced
Recent events (2)
- — I (S) $200.00
- — Z (S) $375.00
1910.107 B05 I
- Issued
- Sep 6, 2006
- Abate by
- Sep 11, 2006
- Penalty
- Initial $375 · Current $200 Reduced
Recent events (2)
- — I (S) $200.00
- — Z (S) $375.00
1910.132 D02
- Issued
- Sep 6, 2006
- Abate by
- Oct 24, 2006
1910.133 A02
- Issued
- Sep 6, 2006
- Abate by
- Oct 2, 2006
1910.305 B01
- Issued
- Sep 6, 2006
- Abate by
- Oct 2, 2006
1910.305 B02
- Issued
- Sep 6, 2006
- Abate by
- Oct 2, 2006
1910.305 G01 IIID
- Issued
- Sep 6, 2006
- Abate by
- Oct 2, 2006
1910.1200 E01
- Issued
- Sep 6, 2006
- Abate by
- Oct 24, 2006
1910.1200 F05 I
- Issued
- Sep 6, 2006
- Abate by
- Sep 11, 2006
More inspections at Caldwell Design & Fabrication, LLC.
View Caldwell Design & Fabrication, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 336612)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310042841.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.