WARWICK, RI ·
OSHA Inspection: NATIONAL VELOUR CORP.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NATIONAL VELOUR CORP. in 36 BELLAIR AVE, WARWICK, RI 02886 (NAICS 313230). OSHA activity number 310158464.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL VELOUR CORP.
- Site address
- 36 BELLAIR AVE
- City
- WARWICK
- State
- RI
- ZIP
- 02886
- Mailing
- 36 BELLAIR AVE, WARWICK, RI 02886
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 313230
- SIC code (legacy)
- 2297
- Employees
- 20
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- May 5, 2008
- Abate by
- Oct 29, 2008
- Penalty
- Initial $1,500 · Current $750 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and/or explosion. a) Flocking Rooms: The employer is mixing flock to color it in a barrel mixer and then emptying the flock onto the floor to shovel it into the flocking line. The mixer is installed inside and a fire and explosion suppression system was not installed within the flocking rooms in accordance with National Fire Protection Association (NFPA) 654. b) Rear Flocking Room: The room was being heated by a wall mounted Sterling QV gas fired heater, providing an ignition source which exposed employees to fire and explosion hazards. "ABATEMENT NOTE" Among other methods, one feasible and acceptable means of abatement would be to comply with the guidelines outlined in the NFPA 654, Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids (2006 Edition), such as but not limited to Sections 6, 7, 8, 9, 10, 11 and 12. "DOCUMENTATION IS REQUIRED"ATION
Recent events (3)
- · F (S) $750.00
- · I (S) $750.00
- · Z (S) $1500.00
1910.22 A01
- Issued
- May 5, 2008
- Abate by
- Oct 29, 2008
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- · I (S) $750.00
- · Z (S) $1500.00
1910.22 A02
- Issued
- May 5, 2008
- Abate by
- Oct 29, 2008
Recent events (3)
- · F (S)
- · I (S)
- · Z (S)
1910.307 C
- Issued
- May 5, 2008
- Abate by
- May 8, 2008
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (3)
- · F (S) $750.00
- · I (S) $750.00
- · Z (S) $1500.00
More inspections at National Velour Corp.
View National Velour Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 313230)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 310158464.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.