MOMENCE, IL —
OSHA Inspection: MOMENCE PACKING COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MOMENCE PACKING COMPANY, INC. in 334 WEST NORTH STREET, MOMENCE, IL 60954 (NAICS 311611). OSHA activity number 310174925.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOMENCE PACKING COMPANY, INC.
- Site address
- 334 WEST NORTH STREET
- City
- MOMENCE
- State
- IL
- ZIP
- 60954
- Mailing
- 334 WEST NORTH STREET, MOMENCE, IL 60954
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311611
- SIC code (legacy)
- 2011
- Employees
- 230
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 5, 2007
- Abate by
- Mar 6, 2008
- Penalty
- Initial $1,375 · Current $963 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to inhalation hazards associated with anhydrous ammonia. Machinery room - On or about March 07, 2007, employees were not adequately protected against the potential release of anhydrous ammonia in that: a. Visual and audible alarms were not located on the outside of each entrance so that employees are fully aware of the conditions inside the machinery room prior to entry. b. The space containing the refrigeration machinery was not separated from other occupancies (such as the maintenance shop and water treatment room) by tight construction with tight-fitting doors. c. The overhead fire door in the machinery room was not suitable to ensure freedom for employees to escape in an emergency. d. Not all controls and piping in anhydrous ammonia service were identified, or labeled, to prevent employees from using the wrong control and/or opening the wrong piping. e. A schematic drawing or panel giving directions for the operation of the refrigeration system was not provided in a location that was convenient to the operators of the equipment to assure they are able to refer to it to minimize the possibility of a mistake. f. Emergency procedures were not posted outside the machinery room, immediately adjacent to each door, to provide directions to operators in case of a breakdown or leak, and including instructions for shutting down the system in case of emergency. g. Pipes piercing the interior walls were not tightly sealed such that any release of anhydrous ammonia would not migrate to other areas of the workplace where employees are present. Among other methods, feasible and acceptable methods to control these hazards are to adhere to the safe design, installation and operation of anhydrous ammonia refrigeration systems as prescribed by ANSI/ASHRAE 15-2004, "Safety Standard for Refrigeration Systems", specifically: a. Provide visual and audible alarms outside each entrance to the machinery room. (Section 8.11) b. Separate the space containing the machinery from other occupancies by tight construction with tight-fitting doors.(Section 7) c. Provide an adequate number of doors that are tight fitting and open outward and adequate in number to ensure freedom for persons to escape in an emergency.(Section 8.11) d. Identify/label all controls and piping in anhydrous ammonia service. (Section 11.2) e. Provide a schematic drawing or panel giving directions for the operation of the refrigeration system in a location convenient for the operators. (Section 11.7) f. Post emergency procedures outside the machinery room immediately adjacent to each door. (Section 11.7) g. Seal pipes piercing the walls of the machinery room. (Section 8.12)ion
Recent events (2)
- — I (S) $962.50
- — Z (S) $1375.00
1910.1200 F05 II
- Issued
- Sep 5, 2007
- Abate by
- Oct 23, 2007
More inspections at Momence Packing Company, INC.
View Momence Packing Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311611)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310174925.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.