SUGARLAND, TX ·
OSHA Inspection: NALCO COMPANY ENERGY SERVICES DIVISION
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of NALCO COMPANY ENERGY SERVICES DIVISION in 7701 HWY. 90-A, P.O.BOX 87, SUGARLAND, TX 77487 (NAICS 325998). OSHA activity number 310260211.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NALCO COMPANY ENERGY SERVICES DIVISION
- Site address
- 7701 HWY. 90-A, P.O.BOX 87
- City
- SUGARLAND
- State
- TX
- ZIP
- 77487
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- SIC code (legacy)
- 2899
- Employees
- 238
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 8, 2007
- Abate by
- Jun 10, 2007
- Penalty
- Initial $4,500 · Current $4,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: ***Certification AND Documentation of Abatement Required*** (a)At Nalco, 7701 Hwy 90-A, Sugarland, TX, employees were exposed to the hazards of fire, explosion, inhalation and skin hazards when heating a truck trailer containing ethylenediamine which changed its properties from a combustible to a flammable. A feasible and acceptable method to abate the hazard would be to: Comply with National Fire Protection Code, NFPA 30, Flammable and Combustible Liquids Code, Chapter 1, General Provisions, 1-1.3, When Class II or Class III liquids are exposed to storage conditions, use conditions or process operations where they are naturally or artificially heated to or above their flash points, additional requirements may be necessary. These requirements include consideration for such items as ventilation, exposure to ignition sources, diking, and electrical area classifications. Develop and implement a procedure to ensure Class II and Class III liquids do not reach a flammable/explosive limit and remove potential ignitions sources such as but not limited to diesel engines.