Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PENRECO

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of PENRECO in 4401 PARK AVENUE, DICKINSON, TX 77539 (NAICS 324199). OSHA activity number 310260872.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Penreco — free Get an email when a new federal OSHA severe-injury report for Penreco is published. One employer, no account, unsubscribe in one click.
Establishment
PENRECO
Site address
4401 PARK AVENUE
City
DICKINSON
State
TX
ZIP
77539
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324199
SIC code (legacy)
2999
Employees
50
Ownership type
A

15 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 5 instances 4 exposed
Issued
Aug 3, 2007
Abate by
Sep 5, 2007
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to:
***Certification AND Documentation of Abatement Required***
(a)At the Penreco plant in Dickinson Texas, storage vessel T-353 and T-354
have inspection
points with wall thickness below the alarm/minimum thickness. (Reference
API 653 -
Minimum Thickness Calculation.)
(b)At the Penreco plant in Dickinson Texas, per the July 2000 inspection,
vessel T-353 and
T-354 were recommended and scheduled to be inspected (Ultrasonic Test) by
December
2000. The scheduled inspection was not conducted.  (Reference API 653 -
Minimum
Thickness Calculation)
Among other methods, one feasible and acceptable abatement method is to
conduct inspection and
repair in accordance to API 653.
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

1910.119 E05

Serious Gravity 02 1 instance 4 exposed
Issued
Aug 3, 2007
Abate by
Sep 5, 2008
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

1910.119 E06

Serious Gravity 02 1 instance
Issued
Aug 3, 2007
Abate by
Sep 5, 2007
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

1910.119 F04

Serious Gravity 02 1 instance 4 exposed
Issued
Aug 3, 2007
Abate by
Sep 5, 2007
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

1910.119 J04 I

Serious Gravity 02 1 instance 4 exposed
Issued
Aug 3, 2007
Abate by
Jan 5, 2008
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

1910.119 J04 III

Serious Gravity 05 3 instances 4 exposed
Issued
Aug 3, 2007
Abate by
Oct 5, 2007
Penalty
Initial $2,625 · Current $2,625
Recent events (2)
  • — I (S) $2625.00
  • — Z (S) $2625.00

1910.119 J05

Serious Gravity 02 3 instances 4 exposed
Issued
Aug 3, 2007
Abate by
Oct 5, 2007
Recent events (2)
  • — I (S)
  • — Z (S)

1910.119 L01

Serious Gravity 02 1 instance 4 exposed
Issued
Aug 3, 2007
Abate by
Jan 5, 2008
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

1910.119 L02 V

Serious Gravity 01 1 instance 4 exposed
Issued
Aug 3, 2007
Abate by
Sep 5, 2007
Recent events (2)
  • — I (S)
  • — Z (S)

1910.120 Q02 II

Serious Gravity 02 1 instance 4 exposed
Issued
Aug 3, 2007
Abate by
Oct 5, 2007
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

1910.120 Q02 IV

Serious Gravity 02 1 instance 4 exposed
Issued
Aug 3, 2007
Abate by
Oct 5, 2007
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

1910.132 D01

Deleted Serious Gravity 02 1 instance 4 exposed
Issued
Aug 3, 2007
Abate by
Sep 5, 2007
Penalty
Initial $1,500
Recent events (2)
  • — I (S)
  • — Z (S) $1500.00

1910.147 C05 IIA2

Serious Gravity 02 1 instance 4 exposed
Issued
Aug 3, 2007
Abate by
Sep 5, 2007
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

1910.147 C05 IIC2

Serious Gravity 02 1 instance 1 exposed
Issued
Aug 3, 2007
Abate by
Aug 11, 2007
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

1910.165 B02

Serious Gravity 02 1 instance 4 exposed
Issued
Aug 3, 2007
Abate by
Oct 5, 2007
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — I (S) $1500.00
  • — Z (S) $1500.00

View Penreco's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310260872.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.