PASADENA, TX ·
OSHA Inspection: CALPINE CHANNEL CENTER ENERGY
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of CALPINE CHANNEL CENTER ENERGY in 12000 LAWNDALE, PASADENA, TX 77017 (NAICS 221122). OSHA activity number 310261953.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CALPINE CHANNEL CENTER ENERGY
- Site address
- 12000 LAWNDALE
- City
- PASADENA
- State
- TX
- ZIP
- 77017
- Mailing
- P.O. BOX 1537, PASADENA, TX 77501
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221122
- SIC code (legacy)
- 4911
- Employees
- 28
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jul 25, 2007
- Abate by
- Aug 27, 2007
- Penalty
- Initial $5,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that chemical unloading procedures were inadequate: At 12000 Lawndale, Gate 5, Pasadena, TX 77017, on or about April 11, 2007, the operating procedure for the unloading of hydrochloric acid (HCL) from delivery truck (tanker) to the facility's HCL's storage was inadequate in that the procedure did not contain the following information: Steps necessary to verify the liquid level in the HCL delivery truck tanker. Steps necessary to inform the delivery truck driver/unloader that the HCL transfer was complete. The driver who monitored the HCL transfer operation had no means of verifying the HCL quantity that remained in the delivery truck tanker other than visually looking for the hammer effect on the transfer hose. The allowable flow limits (air pressure) for the HCL transfer operation. Means such as radio or unit alarm for the delivery truck driver/unloader to warn the board operator and other workers nearby of an emergency release such as the HCL release that occurred on or about March 28, 2007. ***Certification AND Documentation of Abatement Required*** Among other methods, one feasible and acceptable abatement method is to install engineering controls and administrative controls to monitor the liquid level in the hydrochloric acid storage tank. Also, engineering controls to monitor the flow rate for the HCL transfer operation. The administrative controls can be in the form of specific written operation procedures. DISCLAIMERS: 1) You are not limited to the abatement methods suggested above. 2) The methods explained are general and may not be effective in all cases. 3) The employer is responsible for selection and carrying out an appropriate abatement method.