LAS VEGAS, NV —
OSHA Inspection: NEVADA RADIATOR SERVICE, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of NEVADA RADIATOR SERVICE, INC. in 1114 S. MAIN STREET, LAS VEGAS, NV 89104 (NAICS 811198). OSHA activity number 310423413.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEVADA RADIATOR SERVICE, INC.
- Site address
- 1114 S. MAIN STREET
- City
- LAS VEGAS
- State
- NV
- ZIP
- 89104
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811198
- SIC code (legacy)
- 7539
- Employees
- 7
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
36 citations on file for this inspection.
618037501
- Issued
- Nov 9, 2006
- Abate by
- Nov 15, 2006
- Penalty
- Initial $1,500 · Current $900 Reduced
General-duty citation text
Nevada Revised Statute 618.375(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a.Shop employees were exposed to potential injuries resulting from the failure of schedule 40 PVC pipe, used to distribute up to 125 psi of compressed air, which is not recommended by the manufacturer. Fatigue and heat breakdown of the PVC pipe can result in sudden rupture of the pipe and potential fragmentation, exposing employees to flying fragments of the PVC pipe. One feasible method, among others, would be to replace the PVC pipe with a pipe capable of withstanding compressed air distribution. Reference: PVC manufacturers' data cautions and warning notice states "Do not use compressed air or gas for pressure testing. PVC and CPVC products are not recommended for the use in compressed air or gas systems", and "The manufacturers does not recommend its PVC or CPVC products for use in air or compressed gas systems. PVC and CPVC pipes, fittings, and valves are excellent products for the transport of water and corrosive chemicals., but there are a number of other piping products that are especially designed and suited for compressed air and gases", and finally, from PW Pipes to the manufacturer in this case, "Do not use PVC pipe for pressurizing air systems. Injuries or death may result due to the catastrophic nature of the pipes, should failure occur. Rapid expansion of compressed air could propel shards of plastic through the area." A general duty serious citation will be proposed for this safety hazard.
Recent events (2)
- — I (S) $900.00
- — Z (S) $1500.00
1910.242 B
- Issued
- Nov 9, 2006
- Abate by
- Feb 9, 2007
- Penalty
- Initial $1,050 · Current $630 Reduced
Recent events (3)
- — P (S) $630.00
- — I (S) $630.00
- — Z (S) $1050.00
1910.243 B02
- Issued
- Nov 9, 2006
- Abate by
- Nov 15, 2006
Recent events (2)
- — I (S)
- — Z (S)
1910.134 E01
- Issued
- Nov 9, 2006
- Abate by
- Feb 9, 2007
- Penalty
- Initial $1,500 · Current $900 Reduced
B14119111430S3300040
Recent events (3)
- — P (S) $900.00
- — I (S) $900.00
- — Z (S) $1500.00
1910.134 F01
- Issued
- Nov 9, 2006
- Abate by
- Feb 9, 2007
B14119111430S3300040
Recent events (3)
- — P (S)
- — I (S)
- — Z (S)
1910.134 F05 I
- Issued
- Nov 9, 2006
- Abate by
- Nov 15, 2006
B14119111430S3300040
Recent events (2)
- — I (S)
- — Z (S)
1910.134 G01 IA
- Issued
- Nov 9, 2006
- Abate by
- Nov 15, 2006
B14119111430S3300040
Recent events (2)
- — I (S)
- — Z (S)
1910.134 H01 I
- Issued
- Nov 9, 2006
- Abate by
- Nov 15, 2006
B14119111430S3300040
Recent events (2)
- — I (S)
- — Z (S)
1910.134 K01 I
- Issued
- Nov 9, 2006
- Abate by
- Feb 9, 2007
B14119111430S3300040
Recent events (3)
- — P (S)
- — I (S)
- — Z (S)
1910.215 A04
- Issued
- Nov 9, 2006
- Abate by
- Nov 15, 2006
- Penalty
- Initial $1,500 · Current $900 Reduced
Recent events (2)
- — I (S) $900.00
- — Z (S) $1500.00
1910.215 B09
- Issued
- Nov 9, 2006
- Abate by
- Nov 15, 2006
Recent events (2)
- — I (S)
- — Z (S)
1910.219 E01 I
- Issued
- Nov 9, 2006
- Abate by
- Nov 15, 2006
- Penalty
- Initial $1,500
Recent events (2)
- — I (S)
- — Z (S) $1500.00
1910.303 F
- Issued
- Nov 9, 2006
- Abate by
- Nov 15, 2006
- Penalty
- Initial $1,500 · Current $900 Reduced
Recent events (2)
- — I (S) $900.00
- — Z (S) $1500.00
1910.305 B01
- Issued
- Nov 9, 2006
- Abate by
- Nov 15, 2006
Recent events (2)
- — I (S)
- — Z (S)
1910.1025 D01 II
- Issued
- Nov 9, 2006
- Abate by
- Feb 9, 2007
- Penalty
- Initial $1,500 · Current $900 Reduced
15911592
Recent events (3)
- — P (S) $900.00
- — I (S) $900.00
- — Z (S) $1500.00
1910.1025 D02
- Issued
- Nov 9, 2006
- Abate by
- Feb 9, 2007
15911592
Recent events (3)
- — P (S)
- — I (S)
- — Z (S)
1910.1025 H02 I
- Issued
- Nov 9, 2006
- Abate by
- Feb 9, 2007
15911592
Recent events (3)
- — P (S)
- — I (S)
- — Z (S)
1910.1025 L01 I
- Issued
- Nov 9, 2006
- Abate by
- Feb 9, 2007
15911592
Recent events (3)
- — P (S)
- — I (S)
- — Z (S)
1910.1200 E01
- Issued
- Nov 9, 2006
- Abate by
- Feb 9, 2007
- Penalty
- Initial $1,500
2260B14119111430S330
Recent events (3)
- — P (S)
- — I (S)
- — Z (S) $1500.00
1910.1200 E01 I
- Issued
- Nov 9, 2006
- Abate by
- Nov 15, 2006
B14119111430S3300040
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 F05
- Issued
- Nov 9, 2006
- Abate by
- Nov 15, 2006
B14119111430S3300040
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 G01
- Issued
- Nov 9, 2006
- Abate by
- Nov 15, 2006
B14119111430S3300040
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 H01
- Issued
- Nov 9, 2006
- Abate by
- Feb 9, 2007
B14119111430S3300040
Recent events (3)
- — P (S)
- — I (S)
- — Z (S)
618038304
- Issued
- Nov 9, 2006
- Abate by
- Feb 9, 2007
- Penalty
- Initial $300 · Current $180 Reduced
B14119111430S3300040
Recent events (3)
- — P (O) $180.00
- — I (O) $180.00
- — Z (O) $300.00
6180580
- Issued
- Nov 2, 2006
- Abate by
- Nov 10, 2006
1910.22 A01
- Issued
- Nov 2, 2006
- Abate by
- Nov 7, 2006
1910.37 Q02
- Issued
- Nov 2, 2006
- Abate by
- Nov 7, 2006
1910.132 D01
- Issued
- Nov 2, 2006
- Abate by
- Nov 10, 2006
1910.133 A01
- Issued
- Nov 2, 2006
- Abate by
- Nov 7, 2006
1910.157 C01
- Issued
- Nov 2, 2006
- Abate by
- Nov 7, 2006
1910.253 B04 III
- Issued
- Nov 2, 2006
- Abate by
- Nov 7, 2006
1910.253 B04 III
- Issued
- Nov 2, 2006
- Abate by
- Nov 7, 2006
1910.305 B02
- Issued
- Nov 2, 2006
- Abate by
- Nov 7, 2006
1910.305 G01 IIIA
- Issued
- Nov 2, 2006
- Abate by
- Nov 7, 2006
1910.305 G01 IIIB
- Issued
- Nov 2, 2006
- Abate by
- Nov 10, 2006
1910.305 G02 III
- Issued
- Nov 2, 2006
- Abate by
- Nov 10, 2006
More inspections at Nevada Radiator Service, INC.
View Nevada Radiator Service, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811198)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310423413.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.