Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: T-REX CONOCO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of T-REX CONOCO in 1107 THIRD AVENUE WEST, DICKINSON, ND 58601 (NAICS 811111). OSHA activity number 310448329.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch T-Rex Conoco — free Get an email when a new federal OSHA severe-injury report for T-Rex Conoco is published. One employer, no account, unsubscribe in one click.
Establishment
T-REX CONOCO
Site address
1107 THIRD AVENUE WEST
City
DICKINSON
State
ND
ZIP
58601
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
SIC code (legacy)
7538
Employees
16
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 01 1 instance 1 exposed
Issued
Nov 20, 2006
Abate by
Dec 22, 2006
Penalty
Initial $525 · Current $263 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to potential crushing hazards from falling loads and/or lift
parts:
(a)  Service bay area, 1107 Third Avenue West, Dickinson, ND, for the
employees who
were exposed to potential crushing hazards while using Forward autolifts
where the lifts
had not been routinely inspected or annually serviced.
Abatement Note:
Among other methods, one feasible and acceptable method of abatement would
be to
follow the requirements of ANSI/ALI ALOIM 2000, which include, among other
requirements:
1.  Schedule and complete periodic and annual inspections.
2.  Repair identified deficiencies from either lift operators or qualified
lift inspectors.
3.  Maintain documentation that indicates when a repair or maintenance
procedure has
been performed.
Abatement Note:  Abatement certification is required for this item (see
enclosed "Sample
Abatement Certification Letter").tion
Recent events (2)
  • — I (S) $262.50
  • — Z (S) $525.00

View T-Rex Conoco's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310448329.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.