OSHA Inspection: LEED ENERGY SERVICES, INC

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of LEED ENERGY SERVICES, INC in RIG 721 AT WELD CR 59 AND 62, GILL, CO 80624 (NAICS 213112). OSHA activity number 310463401.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Leed Energy Services, INC — free Get an email when a new federal OSHA severe-injury report for Leed Energy Services, INC is published. One employer, no account, unsubscribe in one click.
Site address
RIG 721 AT WELD CR 59 AND 62
City
GILL
State
CO
ZIP
80624
Mailing
P.O. BOX 329, FORT LUPTON, CO 80621
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
SIC code (legacy)
1389
Employees
5
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 13, 2007
Abate by
Jun 1, 2007
Penalty
Initial $5,600 · Current $5,600
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish a place of employment which was free from recognized hazards that
were causing or
likely to cause death or serious physical harm to employees in that
employees were exposed
to struck by hazards:
(a)LEED Energy Services, Inc. at Rig 721, Weld CR 59 and 62, Gill, CO
80624:
On or before 11/17/06, the employer did not ensure that all hoisting tools
and their
components were substantially constructed to conform with good engineering
practices
and maintained in safe condition, and that no element in the hoisting tool
system was
subjected to any load in excess of its design limitations.  The employer
did not ensure
that the eyelet, used in connecting the upper sheave to the sandline, was
pull tested,
and equipped with a safety latch or equivalent device to prevent
accidental release of
the load being hoisted or lowered.  Condition exposed employees to struck
by
hazards, fatally injuring one employee.
Abatement Note:  Abatement certification and documentation are required
for this item (See
enclosed "Sample Abatement-Certification Letter").
Among other methods, one feasible and acceptable abatement method can be
found in the
American Petroleum Institute Recommended Practice 54 Section 9.7, as
referenced, in part,
above.nced,
Recent events (2)
  • — I (S) $5600.00
  • — Z (S) $5600.00

1910.23 A08

Other-than-serious Gravity 05 1 instance 5 exposed
Issued
Apr 13, 2007
Abate by
Jun 1, 2007
Penalty
Initial $2,800 · Current $2,800
Recent events (2)
  • — I (O) $2800.00
  • — Z (S) $2800.00

1910.23 C01

Deleted Serious Gravity 02 1 instance 5 exposed
Issued
Apr 13, 2007
Abate by
May 2, 2007
Penalty
Initial $1,600
Recent events (2)
  • — I (S)
  • — Z (S) $1600.00

1910.212 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 13, 2007
Abate by
Jun 1, 2007
Penalty
Initial $4,000 · Current $3,000 Reduced
Recent events (2)
  • — I (S) $3000.00
  • — Z (S) $4000.00

View Leed Energy Services, INC's full OSHA safety record →