BRIGHTON, CO —
OSHA Inspection: CONQUEST DISPOSAL SERVICE
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CONQUEST DISPOSAL SERVICE in 1191 WCR 19, BRIGHTON, CO 80601 (NAICS 213112). OSHA activity number 310471768.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONQUEST DISPOSAL SERVICE
- Site address
- 1191 WCR 19
- City
- BRIGHTON
- State
- CO
- ZIP
- 80601
- Mailing
- 8203 W. 20TH AVE.,SUITE A, GREELEY, CO 80634
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- SIC code (legacy)
- 1389
- Employees
- 3
- Ownership type
- A
Citations
14 citations on file for this inspection.
5(a)(1)
- Issued
- May 23, 2008
- Abate by
- Mar 30, 2009
- Penalty
- Initial $2,500 · Current $1,875 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the malfunction of the high level switch on the flammable liquid storage tanks exposed employees to burn hazards: (a) Conquest Disposal Service, Conquest-2 & 1191 WCR 19, Brighton, CO 80601: On January 29, 2008, and at times prior thereto, the employer did not maintain a place of employment which was free of recognized hazards in that tank high level switches for tank numbers 201, 202, 203, and 204 were not maintained in proper working condition. These switches were designed to automatically shut off the pump to prevent tank overfilling. Tank 203 was overfilled on January 29, 2008, due to its high level switch being inoperable. A fire occurred as a result of the overfilling. Abatement Note: The National Fire Protection Association, NFPA30-2008, under Section 21.7- Operation of Storage Tanks. It states: 21.7.1 Prevention of Overfilling of Storage Tanks. Facilities with aboveground tanks larger that 1320 gal (5000 L) storing Class 1 or Class 11 liquids shall establish procedures or shall provide equipment, or both, to prevent overfilling of tanks. 21.7.1.1 Facilities with aboveground tanks that receive and transfer Class 1 liquids from mainline pipelines or marine vessels shall establish and follow formal written procedures to prevent overfilling or tanks utilizing one of the following method of protection: (1)Tanks shall b e gauged at intervals in accordance with established procedures by personnel continuously on the premises during product receipt. Acknowledged communication shall be maintained with the supplier so flow can shut down or diverted in accordance with established procedures. (2)Tanks shall be equipped with high-level detection device that is either independent of any gauging equipment or incorporates a gauging and alarm system that provides electronic self-checking to indicate when he gauging and alarm system has failed. Alarms shall be located where personnel who are on duty throughout product transfer can arrange for flow stoppage or diversion in accordance with established procedures. (3)Tanks shall be equipped with an independent high-level detection system that will automatically shut down or divert flow in accordance with established procedures. Abatement Note: Abatement Certification and documentation are required for this item (see enclosed "Sample Abatement-Certification Letter").-Certification
Recent events (2)
- — F (S) $1875.00
- — Z (S) $2500.00
1910.24 E
- Issued
- May 23, 2008
- Abate by
- Mar 30, 2009
- Penalty
- Initial $1,000 · Current $750 Reduced
Recent events (2)
- — F (O) $750.00
- — Z (S) $1000.00
1910.24 H
- Issued
- May 23, 2008
- Abate by
- Mar 30, 2009
- Penalty
- Initial $1,000 · Current $750 Reduced
Recent events (2)
- — F (O) $750.00
- — Z (S) $1000.00
1910.106 E04 I
- Issued
- May 23, 2008
- Abate by
- Jun 5, 2008
- Penalty
- Initial $1,250
Recent events (2)
- — F (O)
- — Z (S) $1250.00
1910.106 E06 I
- Issued
- May 23, 2008
- Abate by
- Mar 30, 2009
- Penalty
- Initial $2,500 · Current $1,875 Reduced
Recent events (2)
- — F (S) $1875.00
- — Z (S) $2500.00
1910.132 A
- Issued
- May 23, 2008
- Abate by
- Mar 30, 2009
- Penalty
- Initial $2,500 · Current $1,875 Reduced
Recent events (2)
- — F (O) $1875.00
- — Z (S) $2500.00
1910.132 D02
- Issued
- May 23, 2008
- Abate by
- Mar 30, 2009
Recent events (2)
- — F (O)
- — Z (S)
1910.304 G06 VIA
- Issued
- May 23, 2008
- Abate by
- Mar 30, 2009
- Penalty
- Initial $1,250 · Current $938 Reduced
Recent events (2)
- — F (O) $938.00
- — Z (S) $1250.00
1910.305 G01 IVA
- Issued
- May 23, 2008
- Abate by
- Mar 30, 2009
- Penalty
- Initial $1,250 · Current $938 Reduced
Recent events (2)
- — F (O) $938.00
- — Z (S) $1250.00
1910.307 C
- Issued
- May 23, 2008
- Abate by
- Jun 5, 2008
- Penalty
- Initial $2,500 · Current $1,875 Reduced
Recent events (2)
- — F (O) $1875.00
- — Z (S) $2500.00
1910.1200 E02 II
- Issued
- May 23, 2008
- Abate by
- Mar 30, 2009
- Penalty
- Initial $1,250
Recent events (2)
- — F (O)
- — Z (S) $1250.00
1910.1200 F05
- Issued
- May 23, 2008
- Abate by
- Mar 30, 2009
Recent events (2)
- — F (O)
- — Z (S)
1910.1200 G08
- Issued
- May 23, 2008
- Abate by
- Mar 30, 2009
- Penalty
- Initial $1,250
Recent events (2)
- — F (O)
- — Z (S) $1250.00
1910.1200 H01
- Issued
- May 23, 2008
- Abate by
- Mar 30, 2009
Recent events (2)
- — F (O)
- — Z (S)
More inspections at Conquest Disposal Service
View Conquest Disposal Service's full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310471768.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.