MINOT, ND —
OSHA Inspection: CENEX
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CENEX in 215 CENTRAL AVENUE EAST, MINOT, ND 58701 (NAICS 811111). OSHA activity number 310558556.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CENEX
- Site address
- 215 CENTRAL AVENUE EAST
- City
- MINOT
- State
- ND
- ZIP
- 58701
- Mailing
- 215 CENTRAL AVENUE EAST, MINOT, ND 58701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- SIC code (legacy)
- 7538
- Employees
- 54
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Dec 14, 2006
- Abate by
- Jan 2, 2007
- Penalty
- Initial $1,750 · Current $875 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential crushing hazards from falling loads and/or lift parts: (a) Service bay area, for employees utilizing a Forward 12000 #89011349 4-post lift and a Forward 12000 #89011348 4-post lift where the single-point safety latch mechanisms were wrapped with inner tube and insulation foam materials with potential to affect the latching capability of the lifts. (b) Service bay area, for employees utilizing the Forward 4-post, ALM 2-post and Nussbau 2-post automotive lifts where the ALM manual, Lifting Point Guide and Lifting- it-Right documents were not maintained. (c) Service bay area, for employees utilizing the Forward 4-post, ALM 2-post and Nussbau 2-post automotive lifts where annual inspections of the lift were not performed in accordance with ANSI/ALI ALOIM documents. (d) Service bay area, for employees utilizing the Forward 4-post, ALM 2-post and Nussbau 2-post automotive lifts where annual training relating to the lift operations was not performed in accordance with ANSI/ALI ALOIM documents. Abatement Note: Among other methods, one feasible and acceptable method of abatement would be to follow the requirements of ANSI/ALI ALOIM and/or ANSI B153.1 which includes, among other requirements, the following: 1.Institute a preventive maintenance program according to the manufacturer's specifications. 2.Provide training to employees on proper use and care of the lifts. 3.Ensure all lifts are rated and marked with their load capacity. 4.Schedule and complete all periodic and annual inspections. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S) $875.00
- — Z (S) $1750.00
More inspections at Cenex
View Cenex's full OSHA safety record →
More inspections in this industry (NAICS 811111)
More inspections in ND
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310558556.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.