Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: BEACON POWER

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BEACON POWER in 234 BALLARDVALE STREET, WILMINGTON, MA 01887 (NAICS 221119). OSHA activity number 310581871.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Beacon Power for free Get an email when a new federal OSHA severe-injury report for Beacon Power is published. One employer, no account, unsubscribe in one click.
Establishment
BEACON POWER
Site address
234 BALLARDVALE STREET
City
WILMINGTON
State
MA
ZIP
01887
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221119
SIC code (legacy)
4911
Employees
40
Ownership type
A

9 citations on file for this inspection.

1910.22 A01

Serious Gravity 01 1 instance 3 exposed
Issued
Jun 20, 2007
Abate by
Jul 24, 2007
Penalty
Initial $750 · Current $500 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to crushing hazards:
(a) Location - Test area:
On or about 12/28/06, employees were exposed to crushing hazards while
working with
overhead, underhung cranes that were not tested and inspected in
accordance with ANSI
B30.11-1980.
Among other methods, one feasible and acceptable means to correct this
hazard would
be to have qualified individuals test and inspect the cranes in accordance
with ANSI B-
30.11-1980.  Conduct an acceptance load test of not more than 125of the
rated load
upon initial use.
Daily or before each use (daily to monthly intervals):
All functional operating mechanisms for maladjustment interfering with
proper operation.
Deterioration or leakage in lines, tanks, valves, drain pumps, and other
parts of air or
hydraulic systems. Rope reeving for noncompliance with manufacturer's
recommendations.  Hoist chains, including end connections, for excessive
wear, twist,
distorted links interfering with proper function, or stretch beyond
manufacturer's
recommendations. Visually inspect daily; monthly inspection with a
certification record
which includes the date of inspection, the signature of the person who
performed the
inspection and an identifier of the chain which was inspected.
Hooks with deformation or cracks. Visually inspect daily; monthly
inspection with a
certification record which includes the date of inspection, the signature
of the person who
performed the inspection and the serial number, or other identifier, of
the hook
inspected.
Discard hooks with cracks or having more than 15 percent in excess of
normal throat
opening or more than 10 percent twist from the plane of the unbent hook
Periodic: (1-12 month intervals):
Have qualified individuals inspect and document:  findings of deformed,
cracked, or
corroded members.  Inspect for:  Loose bolts or rivets, cracked or worn
sheaves and
drums.  Worn, cracked or distorted parts such as pins, bearings, shafts,
gears, rollers,
locking and clamping devices.  Excessive wear on brake system parts,
linings, pawls,
and ratchets.  Load, wind, and other indicators over their full range, for
any significant
inaccuracies.  Gasoline, diesel, electric, or other powerplants for
improper performance
or noncompliance with applicable safety requirements.  Excessive wear of
chain drive
sprockets and excessive chain stretch.  Electrical apparatus, for signs of
pitting or any
deterioration of controller contactors, limit switches and pushbutton
stations.
Recent events (2)
  • · I (S) $500.00
  • · Z (S) $750.00

1910.22 A01

Serious Gravity 01 1 instance 3 exposed
Issued
Jun 20, 2007
Abate by
Jul 24, 2007
Penalty
Initial $750 · Current $375 Reduced
Recent events (2)
  • · I (S) $375.00
  • · Z (S) $750.00

1910.137 B02 VIII

Serious Gravity 03 2 instances 2 exposed
Issued
Jun 20, 2007
Abate by
Jul 24, 2007
Penalty
Initial $1,250 · Current $625 Reduced
Recent events (2)
  • · I (S) $625.00
  • · Z (S) $1250.00

1910.184 D

Serious Gravity 01 1 instance 3 exposed
Issued
Jun 20, 2007
Abate by
Jul 24, 2007
Penalty
Initial $750 · Current $375 Reduced
Recent events (2)
  • · I (S) $375.00
  • · Z (S) $750.00

1910.303 B02

Serious Gravity 03 2 instances 3 exposed
Issued
Jun 20, 2007
Abate by
Jul 24, 2007
Penalty
Initial $1,250 · Current $625 Reduced
Recent events (2)
  • · I (S) $625.00
  • · Z (S) $1250.00

1910.303 F

Serious Gravity 02 4 instances 3 exposed
Issued
Jun 20, 2007
Abate by
Jul 24, 2007
Penalty
Initial $1,000 · Current $1,000
Recent events (2)
  • · I (S) $1000.00
  • · Z (S) $1000.00

1910.303 G02 I

Serious Gravity 03 1 instance 3 exposed
Issued
Jun 20, 2007
Abate by
Jul 24, 2007
Penalty
Initial $1,250
Recent events (2)
  • · I (S)
  • · Z (S) $1250.00

1910.305 B01

Serious Gravity 02 1 instance 2 exposed
Issued
Jun 20, 2007
Abate by
Jul 24, 2007
Penalty
Initial $1,000
Recent events (2)
  • · I (S)
  • · Z (S) $1000.00

1910.146 C01

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
Jun 20, 2007
Abate by
Jul 24, 2007
Recent events (2)
  • · I (O)
  • · Z (O)

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310581871.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.