On , OSHA opened a planned safety inspection of NABORS DRILLING USA, LP RIG #768 in FM 2294, SAN ISIDRO, TX 78588 (NAICS 213111). OSHA activity number 310584164.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NABORS DRILLING USA, LP RIG #768
- Site address
- FM 2294
- City
- SAN ISIDRO
- State
- TX
- ZIP
- 78588
- Mailing
- 3840 E. HWY 44, ALICE, TX 78332
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- SIC code (legacy)
- 1381
- Employees
- 14
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 3, 2007
- Abate by
- Apr 9, 2007
- Penalty
- Initial $1,875 · Current $1,125 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards: a.At this inspection site, on December 20, 2006, and at other times prior thereto, the guylines were improperly installed for holding the blowout preventers upright, and included the following visible deficiencies: 1.The Crosby clips used to create an eye were installed incorrectly by placing the saddle on the dead end of the wire rope. 2.The Crosby clips used to create an eye made a large loop instead of using a thimble with the wire rope wrapped around it. 3.The large turnbuckle with the jaws and a threaded bolt with a hole drilled through the end of the threaded end, contained a nut which was threaded on, however the cotter key retaining pin was missing. Among other methods, one feasible and acceptable abatement method involves the installing of guylines according to The Crosby Group, Inc.'s recommended guidelines. b.At this inspection site, on December 20, 2006, and at other times prior thereto, eight pressurized rubber hoses, two inches in diameter, were badly deteriorated at: 1.At a vertical wall approximately four foot tall in close proximity to the Koomey Accumulator on the East side of the substructure. 2.At the blowout preventer located under the rig floor at the cellar. Among other methods, one feasible and acceptable abatement method, involves the replacement of the deteriorated pressurized rubber hoses, in accordance with Section 9, Sub-Section 9.13, Paragraph 9.13.4 of the American Petroleum Institute's Recommended Practice 54, (3rd Edition; August 1999).
Recent events (2)
- · I (S) $1125.00
- · Z (S) $1875.00
5(a)(1)
- Issued
- Apr 3, 2007
- Abate by
- Apr 9, 2007
- Penalty
- Initial $1,875 · Current $1,125 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a fire and explosion: At this inspection site, on December 20, 2006, and at other times prior thereto, the auxiliary escape line was installed in an unsafe manner and included the following visible deficiencies: a.A securely anchored one-half inch wire rope escape line was not attached to derrick or mast so as to provide a ready and convenient means of escape from the Derrickman's working platform. b.The Emergency Escape Device was installed on the wire rope escape line which was secured to a ring that had been welded to the top of a steel pipe in the North side guardrail system which permitted the upside down "T" bar to be below the walking surface of the pipe racking board. c.The one-half inch wire rope escape line was approximately thirty-seven feet short and would not assure a safe landing and allow the Derrickman to stop twenty to twenty-five feet from the anchor point. Among other methods, one feasible and acceptable abatement method involves the employer ensuring the emergency escape line system is installed in accordance with American Petroleum Institute Recommended Practice 54 (3rd Edition; August 1999) Section 6, Sub-Section 6.10, Paragraph 6.10.1 and Geronimo Manufacturing Operators Manual guidelines.
Recent events (2)
- · I (S) $1125.00
- · Z (S) $1875.00
1910.242 A
- Issued
- Apr 3, 2007
- Abate by
- Dec 20, 2006
- Penalty
- Initial $956 · Current $573 Reduced
Recent events (2)
- · I (S) $573.00
- · Z (S) $956.00
1910.305 G02 II
- Issued
- Apr 3, 2007
- Abate by
- Apr 9, 2007
- Penalty
- Initial $1,875 · Current $562 Reduced
Recent events (2)
- · I (S) $562.00
- · Z (S) $1875.00
1910.305 G02 III
- Issued
- Apr 3, 2007
- Abate by
- Apr 9, 2007
- Penalty
- Initial $1,875 · Current $563 Reduced
Recent events (2)
- · I (S) $563.00
- · Z (S) $1875.00
1910.307 B
- Issued
- Apr 3, 2007
- Abate by
- Apr 9, 2007
- Penalty
- Initial $1,875 · Current $1,125 Reduced
Recent events (2)
- · I (S) $1125.00
- · Z (S) $1875.00
1910.307 B02 II
- Issued
- Apr 3, 2007
- Abate by
- Apr 9, 2007
Recent events (2)
- · I (S)