Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RANOR, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of RANOR, INC. in BELLA DRIVE, WESTMINSTER, MA 01473 (NAICS 332313). OSHA activity number 310624614.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ranor, INC. — free Get an email when a new federal OSHA severe-injury report for Ranor, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
RANOR, INC.
Site address
BELLA DRIVE
City
WESTMINSTER
State
MA
ZIP
01473
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332313
SIC code (legacy)
3443
Employees
130
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 10 exposed
Issued
Sep 13, 2007
Abate by
Oct 10, 2007
Penalty
Initial $2,500 · Current $2,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm in that
employees were exposed
to fire and explosion hazards.
Establishment:  On or about 8/10/07, an employee opened liquefied
petroleum gas cylinders to
feed a heating torch and escaping gas ignited and burned the employee.
Feasible and acceptable abatement methods include:
1)  Use quarter-turn valves on fuel supply cylinders that indicate the
position of the valve in the
on or off position.
2)  Use flame detecting controls to stop the flow of fuel gas in the
absence of a flame.
3)  Develop and implement standard operating procedures and ensure the
employees follow
correct procedures when using fuel gas and heating torch equipment.
4)  Train employees in the hazards, standard operating procedures, and
proper use of fuel gas
and heating torch equipment.
Recent events (2)
  • — I (S) $2500.00
  • — Z (S) $2500.00

View Ranor, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310624614.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.