Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: CENTURY FOODS INTERNATIONAL

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CENTURY FOODS INTERNATIONAL in 400 CENTURY COURT, SPARTA, WI 54656 (NAICS 311514). OSHA activity number 310768882.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Century Foods International for free Get an email when a new federal OSHA severe-injury report for Century Foods International is published. One employer, no account, unsubscribe in one click.
Site address
400 CENTURY COURT
City
SPARTA
State
WI
ZIP
54656
Mailing
P.O. BOX 257, SPARTA, WI 54656
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311514
SIC code (legacy)
2023
Employees
215
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Feb 18, 2009
Abate by
Mar 23, 2009
Penalty
Initial $4,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
caused or were likely to cause death or serious physical harm in that
employees were exposed
to the hazard of potential fire and explosion from bag house, nuisance
dust collectors, fluid bed
cyclones, fluid bed driers and pneumatic dust collectors were not designed
to minimize damage
that would occur in the event of a dust explosion inside the machines.
a) Agglomeration Process-the bag house, fluid bed cyclones, fluid bed
driers that process
combustible whey dust did not have explosion prevention systems such as
containment,
suppression, inerting, and/or explosion venting.
b) Dry Blending Process- the dust collectors and pneumatic that handle
combustible whey dust
did not have explosion prevention systems, such as containment,
suppression, inerting and/or
explosion venting.
"AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT
METHODS TO CORRECT THIS HAZARD" is to comply with the National Fire
Protection
Association (NFPA) Chapter 61 "Prevention of Fires and Dust Explosion in
Agriculture and
Food Processing Facilities" 2008 edition and NFPA 69 "Standard on
Explosion Prevention
Systems." and NFPA 68 "Standard on Explosion Protection by Deflagration
Venting."
a) Equip big bag house and dust collectors with deflagration venting,
vented to the outside.
b) Install deflagration system suppression system and deflagration
pressure containment system
for the all Agglomeration and Dry Blending operations in accordance with
NFPA 69.
c) Install spark detection devices inside pneumatic conveyor systems used
in Agglomeration and
Dry Blending processes.
Recent events (2)
  • · F (S)
  • · Z (S) $4500.00

5(a)(1)

Deleted Serious Gravity 10 3 instances 3 exposed
Issued
Feb 18, 2009
Abate by
Mar 23, 2009
Penalty
Initial $4,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer
did not
furnish employment and a place of employment which were free from
recognized hazards that
caused or were likely to cause death or serious physical harm in that
employees were exposed
to potential combustible whey dust fire and explosion hazards due to lack
of static energy control
during the filling and emptying whey from non-static dissipating flexible
intermediate bulk
container (FIBC).
In the agglomeration, dry blending and packaging departments, There was
not means to control
static electricity generated during the emptying of combustible whey dust
from non-static
dissipating flexible intermediate bulk containers (FIBC), super sacs.
ABATEMENT NOTE:  Among other methods, one feasible and acceptable
abatement method
to correct this hazard is to comply with National Fire Protection
Association (NFPA) 77
Recommended Practice on Static Electricity Chapter 10 Specific
Application, 10.1.6 Flexible
Intermediate Bulk Containers (FIBC) and 10.1.7 Container Linings.
Recent events (2)
  • · F (S)
  • · Z (S) $4500.00

1910.23 A09

Deleted Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Feb 18, 2009
Abate by
Feb 24, 2009
Recent events (2)
  • · F (O)
  • · Z (O)

View Century Foods International's full OSHA safety record →