PORTAGE, WI ·
OSHA Inspection: TRIENDA, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TRIENDA, LLC in N 7660 INDUSTRIAL ROAD, PORTAGE, WI 53901 (NAICS 325991). OSHA activity number 310769195.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRIENDA, LLC
- Site address
- N 7660 INDUSTRIAL ROAD
- City
- PORTAGE
- State
- WI
- ZIP
- 53901
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325991
- SIC code (legacy)
- 3087
- Employees
- 259
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Apr 15, 2009
- Abate by
- Jul 27, 2009
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that caused or were likely to cause death or serious physical harm in that employees were exposed to the hazard of potential fire and explosion from the cyclone located inside the building without being designed to minimize damage that would occur in the event of an explosion. The Thermo-Former 15 grinder/cyclone collection system, used to collect combustible dust, did not have an explosion protection system. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD is to comply with the National Fire Protection Association (NFPA) 654 "Standard of the Prevention of Fire and Dust Explosion from the Manufacturing, Processing and Handling of Combustible Particulate Solids," 2006 edition; NFPA 68 "Standard on Explosion Protection by Deflagration Venting," 2007 edition; NFPA 69 "Standard on Explosion Prevention System," 2008 edition. Install deflagration venting, to a safe location.
Recent events (2)
- · I (S) $3150.00
- · Z (S) $4500.00
More inspections at Trienda, LLC
View Trienda, LLC's full OSHA safety record →