DEERFIELD, WI —
OSHA Inspection: MPI INTERNATIONAL, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of MPI INTERNATIONAL, INC. in 54 GOLF DRIVE, DEERFIELD, WI 53531 (NAICS 336370). OSHA activity number 310769328.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MPI INTERNATIONAL, INC.
- Site address
- 54 GOLF DRIVE
- City
- DEERFIELD
- State
- WI
- ZIP
- 53531
- Mailing
- P.O. BOX 468, DEERFIELD, WI 53531
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336370
- SIC code (legacy)
- 3465
- Employees
- 154
- Ownership type
- A
Citations
3 citations on file for this inspection.
1903.19 D01
- Issued
- Sep 29, 2009
- Abate by
- Nov 30, 2009
- Penalty
- Initial $1,000 · Current $400 Reduced
Recent events (2)
- — I (O) $400.00
- — Z (O) $1000.00
1910.1025 D03 I
- Issued
- Mar 20, 2009
- Abate by
- Mar 25, 2009
Recent events (2)
- — I (O)
- — Z (O)
5(a)(1)
- Issued
- Mar 13, 2009
- Abate by
- Aug 31, 2009
- Penalty
- Initial $4,500 · Current $1,575 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that caused or were likely to cause death or serious physical harm in that employees were exposed to the hazard of potential fire and explosion from dust collector for combustible metal dust being located inside the building with being designed to minimize damage that would occur in the event of a dust explosion. The dust collector for the Chrysler cell 9175 brushing of low carbon steel metal operation was at increased risk of a fire or explosion in that it was: a) located inside of the building b) did not have deflagration venting c) portions of the ductwork were constructed with non-conductive flexible hose. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD is to comply with the National Fire Protection Association (NFPA) 484 "Standard for Combustible Metals" 2006 edition; NFPA 91 "Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Noncombustible Particulate Solids," 2004 edition; NFPA 68 "Standard on Explosion Protection by Deflagration Venting" 2007 edition, NFPA 69 "Standard on Explosion Prevention Systems," 2008 edition. a) relocate dust collector to a safe location, outside of the building equip with deflagration venting. b) replace non-conductive ductwork with conductive ductwork.e
Recent events (3)
- — P (S) $1575.00
- — I (S) $1575.00
- — Z (S) $4500.00
More inspections at MPI International, INC.
View MPI International, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336370)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310769328.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.