ONALASKA, WI ·
OSHA Inspection: WEYERHAEUSER NR COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WEYERHAEUSER NR COMPANY in 718 SECOND AVENUE SW, ONALASKA, WI 54650 (NAICS 321912). OSHA activity number 310770482.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WEYERHAEUSER NR COMPANY
- Site address
- 718 SECOND AVENUE SW
- City
- ONALASKA
- State
- WI
- ZIP
- 54650
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321912
- SIC code (legacy)
- 2421
- Employees
- 33
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jun 24, 2009
- Abate by
- Sep 30, 2009
- Penalty
- Initial $1,875 · Current $900 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that caused or were likely to cause death or serious physical harm in that employees were exposed to the hazard of potential fire and explosion from North Yard cyclone and dust collectors not designed to minimize damage that would occur in the event of a dust explosion inside the cyclone or dust collector: The north yard cyclone and bag house were not designed to minimize damage that would occur in the event of a dust explosion: a) The cyclone did not have explosion protection, suppression isolation or inerting or explosion system. b) The dust collector did not have propagation isolation devices to prevent explosion flame front from entering the building. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD is to comply with the National Fire Protection Association (NFPA) 664 "Standard for the Prevention of Fire and Explosion in Wood Processing and Woodworking Facilities," 2002 edition; NFPA 654 "Standard for the Prevention of Fire and Explosion from Manufacturing, Processing and Handling of Combustible Particulate Solids" 2006 edition; NFPA 69 "Standard on Explosion Prevention Systems" 2008 edition; NFPA 68 "Standard on Explosion Protection by Deflagration Venting" 2007 edition, including but not limiting to: a) Equip cyclone with deflagration venting or deflagration suppression system. b) install propagation isolation device between the cyclone and dust collector c) install propagation isolation devices between the dust collector and plant building.
Recent events (2)
- · I (S) $900.00
- · Z (S) $1875.00
More inspections at Weyerhaeuser NR Company
View Weyerhaeuser NR Company's full OSHA safety record →
More inspections in this industry (NAICS 321912)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 310770482.