Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CAPTAIN D'S STORE #3604

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CAPTAIN D'S STORE #3604 in 6301 COLONEL GLENN RD., LITTLE ROCK, AR 72204 (NAICS 722211). OSHA activity number 310830443.

Watch Captain D'S Store #3604 — free Get an email when a new federal OSHA severe-injury report for Captain D'S Store #3604 is published. One employer, no account, unsubscribe in one click.
Site address
6301 COLONEL GLENN RD.
City
LITTLE ROCK
State
AR
ZIP
72204
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722211
SIC code (legacy)
5812
Employees
20
Ownership type
A

15 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2250.00 · Current $1000.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to:
At the facility, two single pole 20 amp circuit breakers used to provide
overcurrent
protection for various equipment such as but not limited to; two microwave
ovens, three
recessed (can) lights and seven pendant lights, were not equipped with
handle ties or a
master handle to disconnect all conductors of the service as required
under Article
230.71(B) of the National Electric Code (NEC), 2005 edition (NFPA 70.) The
microwave ovens were operated at 208 to 230/240 volts alternating current.
This
condition exposed employees to hazards such as but not limited to; being
struck by arc
flashes or exploding parts when resetting breakers, contacting energized
electrical
components, and/or hazards associated with fire from failure of the
overcurrent devices.
This condition existed on or about May 11, 2007 and times thereto.
Among other methods, one feasible and acceptable abatement method to
correct this
hazard is to have an appropriately configured and rated overcurrent
devices (circuit
breakers) installed. Have the entire circuit assessed in terms of the
equipment, wire type
and gauge, and wiring methods. All assessments and work must be performed
by a
qualified person and should be done in accordance with any applicable
State and Local
regulations/codes.
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $2250.00

1910.22 A02

Serious Gravity 02 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $500.00 Reduced
Recent events (2)
  • — I (S) $500.00
  • — Z (S) $1800.00

1910.22 A02

Serious Gravity 02 1 instance 20 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1910.101 B

Other-than-serious Gravity 02 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $1000.00
Recent events (2)
  • — I (O)
  • — Z (S) $1000.00

1910.303 B01

Deleted Serious Gravity 03 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2250.00 · Current $2250.00
Recent events (2)
  • — I (S) $2250.00
  • — Z (S) $2250.00

1910.305 G01 III

Deleted Serious Gravity 03 1 instance 20 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 G01 III

Deleted Serious Gravity 03 1 instance 20 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 B01

Deleted Serious Gravity 03 2 instances 20 exposed
Issued
Abate by
Penalty
Initial $2250.00 · Current $2250.00
Recent events (2)
  • — I (S) $2250.00
  • — Z (S) $2250.00

1910.334 B02

Deleted Serious Gravity 03 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2250.00 · Current $2250.00
Recent events (2)
  • — I (S) $2250.00
  • — Z (S) $2250.00

1910.303 B01

Serious Gravity 03 1 instance 20 exposed
Issued
Abate by
Penalty
Current $1800.00
Recent events (3)
  • — Q $2250.00
  • — I (S) $1800.00
  • — Z (S) $2250.00

1910.305 B01

Serious Gravity 03 2 instances 20 exposed
Issued
Abate by
Recent events (3)
  • — Q $2250.00
  • — I (S)
  • — Z (S) $2250.00

1910.305 G01 III

Serious Gravity 03 1 instance 20 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 G01 III

Serious Gravity 03 1 instance 20 exposed
Issued
Abate by
Recent events (2)
  • — I (S)
  • — Z (S)

1910.334 B02

Serious Gravity 03 1 instance 20 exposed
Issued
Abate by
Recent events (3)
  • — Q $2250.00
  • — I (S)
  • — Z (S) $2250.00

1910.305 B02

Other-than-serious Gravity 01 1 instance 20 exposed
Issued
Abate by
Recent events (2)
  • — I (O)
  • — Z (O)

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310830443.