YORK, PA —
OSHA Inspection: MILTEX, INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MILTEX, INCORPORATED in 589 DAVIES ROAD, YORK, PA 17402 (NAICS 339114). OSHA activity number 310837000.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MILTEX, INCORPORATED
- Site address
- 589 DAVIES ROAD
- City
- YORK
- State
- PA
- ZIP
- 17402
- Mailing
- 589 DAVIES ROAD, YORK, PA 17402
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339114
- SIC code (legacy)
- 3843
- Employees
- 185
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
22 citations on file for this inspection.
5(a)(1)
- Issued
- May 8, 2007
- Abate by
- Dec 31, 2008
- Penalty
- Initial $1,100 · Current $550 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards: (a)Mirror and Etching - Employees used a Cincinnati buffer, type 204-202-8, model SPL, serial number 250327; a Baldor Buffer, number 332B, serial number P3-96; a Dieter Kupferschmid sander/buffer, model number 090002, employer machine number 906; a floor mounted pedestal buffer, employer machine number 907; and a semi-automatic mirror buffer, employer machine number 430 to buff and polish stainless steel and brass dental hand instruments. The employer had this equipment connected to a dust collection system. Ductwork, with numerous 90 degree bends and long runs, connected the dust-producing machinery to a Sternvent dry- type cyclone dust collector. The employer had the Sternvent dry-type cyclone dust collector located inside the building, with no barriers located between the dust collector and personnel, and with no deflagration venting. The employer did not have the buffing and polishing equipment, ductwork, and dust collector bonded and grounded to dissipate the accumulation of static charges. Ductwork, consisting of PVC pipe, a non-conductive material, connected the Cincinnati buffer, type 204-202-8, model SPL, serial number 250327, to the dust collector. Also, the employer did not have the dust collector emptied on a daily basis, on or about March 22, 2007. (b)Mirror and Etching - The employer did not have the power supplies of the buffing and polishing equipment interlocked with the airflow from the exhaust fan on the Sternvent dry- type cyclone dust collector so that improper functioning of the dust collection system would shut down the buffing and polishing equipment. Also, the buffing and polishing equipment did not have time delay switches to prevent the motor drives from starting until the dust collector had reached complete operation, on or about March 22, 2007. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct these hazards includes following the National Fire Protection Association (NFPA) 484, Standard for Combustible Metals, 2006 Edition, including, but not limited to: *Locate dry-type dust collectors outside of the building as listed in Paragraph 12.2.1.4 of NFPA 484-2006. *Provide dry-type dust collectors with barriers or other means for protection of personnel as listed in Paragraph 12.2.1.5 of NFPA 484-2006. *Ensure that ductwork is as straight and short as possible with as few bends and irregularities as possible to prevent interference with free airflow as listed in Paragraph 12.2.5.5 of NFPA 484-2006. *Construct ductwork of conductive material and assemble ductwork with smooth interior surfaces with internal lap joints facing in the direction of airflow, and with seams oriented in a direction away from personnel as listed in Paragraphs 12.2.5.6 and 12.2.5.8 of NFPA 484- 2006. *Bond and ground duct systems, dust collectors, and dust-producing machinery to minimize accumulation of static electric charges as listed in Paragraph 12.2.5.10 of NFPA 484-2006. *Interlock the power supply to the dust-producing equipment with the airflow from the dust collector, so that improper functioning of the dust collection system will shut down the equipment it serves as listed in Paragraph 12.2.8.1 of NFPA 484-2006. *Provide a time delay switch or the equivalent on dust-producing equipment to prevent the starting of the motor drive on the equipment until the collector is in complete operation aslisted in Paragraph 12.2.8.2 of NFPA 484-2006. *Remove dust from dry collectors at least once each day and at more frequent intervals if warranted as listed in Paragraph 12.2.10.6 of NFPA 484-2006. *Provide dry-type dust collectors used for metal dusts with deflagration vents as listed in Paragraph 12.2.10.7 of NFPA 484-2006. VERIFICATION REQUIRED
Recent events (3)
- — P (S) $550.00
- — I (S) $550.00
- — Z (S) $1100.00
1910.94 A02 III
- Issued
- May 8, 2007
- Abate by
- Apr 30, 2008
- Penalty
- Initial $1,100 · Current $550 Reduced
Recent events (3)
- — P (S) $550.00
- — I (S) $550.00
- — Z (S) $1100.00
1910.145 C03
- Issued
- May 8, 2007
- Abate by
- Jun 10, 2007
- Penalty
- Initial $1,100 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $1100.00
1910.147 C06 I
- Issued
- May 8, 2007
- Abate by
- Jun 10, 2007
- Penalty
- Initial $1,100 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $1100.00
1910.147 D03
- Issued
- May 8, 2007
- Abate by
- Jun 10, 2007
Recent events (2)
- — I (S)
- — Z (S)
1910.147 D04 I
- Issued
- May 8, 2007
- Abate by
- Jun 10, 2007
Recent events (2)
- — I (S)
- — Z (S)
1910.147 D05 I
- Issued
- May 8, 2007
- Abate by
- Jun 10, 2007
Recent events (2)
- — I (S)
- — Z (S)
1910.212 A01
- Issued
- May 8, 2007
- Abate by
- May 11, 2007
- Penalty
- Initial $1,100 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $1100.00
1910.212 A03 II
- Issued
- May 8, 2007
- Abate by
- Jun 10, 2007
- Penalty
- Initial $1,100 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $1100.00
1910.215 A02
- Issued
- May 8, 2007
- Abate by
- May 11, 2007
- Penalty
- Initial $1,100 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $1100.00
1910.215 B09
- Issued
- May 8, 2007
- Abate by
- May 11, 2007
- Penalty
- Initial $1,100 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $1100.00
1910.217 B06 I
- Issued
- May 8, 2007
- Abate by
- Sep 10, 2007
- Penalty
- Initial $1,100 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $1100.00
1910.217 B06 II
- Issued
- May 8, 2007
- Abate by
- Jun 10, 2007
1910.217 C01 I
- Issued
- May 8, 2007
- Abate by
- May 11, 2007
- Penalty
- Initial $1,100 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $1100.00
1910.217 C02 IB
- Issued
- May 8, 2007
- Abate by
- May 11, 2007
- Penalty
- Initial $1,100 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $1100.00
1910.217 C03 VIII
- Issued
- May 8, 2007
- Abate by
- Jun 10, 2007
- Penalty
- Initial $1,100 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $1100.00
1910.217 C05 I
- Issued
- May 8, 2007
- Abate by
- Sep 10, 2007
- Penalty
- Initial $1,100 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $1100.00
1910.219 E03 I
- Issued
- May 8, 2007
- Abate by
- May 11, 2007
- Penalty
- Initial $1,100 · Current $550 Reduced
Recent events (2)
- — I (S) $550.00
- — Z (S) $1100.00
1910.219 F03
- Issued
- May 8, 2007
- Abate by
- Jun 10, 2007
- Penalty
- Initial $825 · Current $415 Reduced
Recent events (2)
- — I (S) $415.00
- — Z (S) $825.00
1910.106 E02 IVD
- Issued
- May 8, 2007
- Abate by
- Jun 10, 2007
1910.151 C
- Issued
- May 8, 2007
- Abate by
- May 11, 2007
1910.303 B02
- Issued
- May 8, 2007
- Abate by
- Jun 10, 2007
More inspections at Miltex, Incorporated
View Miltex, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 339114)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310837000.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.