Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GOVESAN MANUFACTURING, INCORPORATED

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of GOVESAN MANUFACTURING, INCORPORATED in 939 MONOCACY ROAD, YORK, PA 17404 (NAICS 325510). OSHA activity number 310845847.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Govesan Manufacturing, Incorporated — free Get an email when a new federal OSHA severe-injury report for Govesan Manufacturing, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
939 MONOCACY ROAD
City
YORK
State
PA
ZIP
17404
Mailing
939 MONOCACY ROAD, YORK, PA 17404
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325510
SIC code (legacy)
2851
Employees
45
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 3 instances 1 exposed
Issued
Dec 18, 2008
Abate by
Jul 20, 2009
Penalty
Initial $875 · Current $620 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to an explosion hazard from inadequate deflagration venting
and lack of backflash
dampers between milling and collection systams:
(a)Milling Area - The deflagration vents on all the Newman & Esser dust
collection
systems, model number CAR60 252/170, used to collect powder coating dust,
were not vented to the outside of the building, on or about September 24,
2008.
(b)Milling Area -  The ventilation duct from all the milling machines to
the NEA
Group dust collection systems did not have backflash dampers to prevent an
explosion from traveling back to the work area, on or about September 24,
2008.
(c)Outside Area - The Dustex 2000 dust collection system located outside,
model
number CJUP 5000, did not have a backflash damper to prevent an explosion
from traveling back to the work area, on or about September 24, 2008.
ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement
method to correct the hazard is to comply with the National Fire
Protection Association
(NFPA 654), "Standard to Prevention of Fire and Dust Explosions for the
Manufacturing, Processing and Handling of Combustible Particulate
Solids"-2006 as it
applies to your operations and equipment including but not limited to:
(a)Install vent ducts for the dust collection system to the outside of the
building in accordance to NFPA 68, Venting of Deflagrations.
(b)Install an isolation device to prevent deflagration propagation from air
material separators upstream to the work areas.
VERIFICATION REQUIRED
Recent events (2)
  • — I (S) $620.00
  • — Z (S) $875.00

1910.305 D02

Serious Gravity 01 1 instance 1 exposed
Issued
Dec 18, 2008
Abate by
Dec 23, 2008
Penalty
Initial $525 · Current $365 Reduced
Recent events (2)
  • — I (S) $365.00
  • — Z (S) $525.00

1910.305 G01 IIIA

Serious Gravity 01 1 instance 1 exposed
Issued
Dec 18, 2008
Abate by
Dec 23, 2008
Penalty
Initial $525 · Current $365 Reduced
Recent events (2)
  • — I (S) $365.00
  • — Z (S) $525.00

1910.307 C02 I

Serious Gravity 01 2 instances 1 exposed
Issued
Dec 18, 2008
Abate by
Dec 23, 2008
Penalty
Initial $525 · Current $365 Reduced
Recent events (2)
  • — I (S) $365.00
  • — Z (S) $525.00

View Govesan Manufacturing, Incorporated's full OSHA safety record →