ATLANTA, GA —
OSHA Inspection: RAYMOND HOOKS D/B/A R.C.E. CONSTRUCTION CO.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RAYMOND HOOKS D/B/A R.C.E. CONSTRUCTION CO. in 5887 FULTON INDUSTRIAL BOULEVARD, ATLANTA, GA 30036 (NAICS 238120). OSHA activity number 310957584.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAYMOND HOOKS D/B/A R.C.E. CONSTRUCTION CO.
- Site address
- 5887 FULTON INDUSTRIAL BOULEVARD
- City
- ATLANTA
- State
- GA
- ZIP
- 30036
- Mailing
- 1844 PLEASANT RIDGE ROAD, LAFOLLETTE, TN 37766
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- SIC code (legacy)
- 1791
- Employees
- 14
- Ownership type
- A
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 22, 2008
- Abate by
- Jul 25, 2008
- Penalty
- Initial $2,500 · Current $2,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to impalement hazards from vertical protruding electrical conduit and plastic water pipe: (a) On or about January 28, 2008, floor level in the large bays of the building: Vertical protruding electrical conduit (1/2 inch, 3/4 inch and 1 inch) and the vertical protruding plastic water pipe (1/2, 3/4 and 1 inch) was not protected or covered. One suitable and acceptable method of abatement for this hazard is to cover the conduit and water pipe with regular rebar caps. ABATEMENT CERTIFICATION AND DOCUMENTATION NOT REQUIRED
1926.701 B
- Issued
- Jul 22, 2008
- Abate by
- Jul 25, 2008
1926.453 B02 V
- Issued
- Jul 22, 2008
- Abate by
- Jul 25, 2008
- Penalty
- Initial $2,500 · Current $2,500
1926.453 B02 IV
- Issued
- Jul 22, 2008
- Abate by
- Jul 25, 2008
- Penalty
- Initial $2,500 · Current $2,500
1926.453 B02 VI
- Issued
- Jul 22, 2008
- Abate by
- Jul 25, 2008
- Penalty
- Initial $2,500 · Current $2,500
1926.602 C01 II
- Issued
- Jul 22, 2008
- Abate by
- Jul 28, 2008
- Penalty
- Initial $2,500 · Current $2,500
1926.760 A01
- Issued
- Jul 22, 2008
- Abate by
- Jul 25, 2008
- Penalty
- Initial $2,500 · Current $2,500
1926.761 B
- Issued
- Jul 22, 2008
- Abate by
- Sep 8, 2008
- Penalty
- Initial $2,500 · Current $2,500
1926.761 C02
- Issued
- Jul 22, 2008
- Abate by
- Sep 8, 2008
More inspections in this industry (NAICS 238120)