Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JAX UTILITIES CONSTRUCTION, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JAX UTILITIES CONSTRUCTION, INC. in 300 NORTH RIVER CAUSEWAY, ST. MARYS, GA 31558 (NAICS 238220). OSHA activity number 310989355.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JAX Utilities Construction, INC. — free Get an email when a new federal OSHA severe-injury report for JAX Utilities Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
300 NORTH RIVER CAUSEWAY
City
ST. MARYS
State
GA
ZIP
31558
Mailing
5253 WEST 12TH ST., JACKSONVILLE, FL 32254
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
SIC code (legacy)
1711
Employees
12
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 21, 2008
Abate by
Oct 31, 2008
Penalty
Initial $2,500 · Current $2,500
P.L. 91-596 Section 5(a)(1) of the Occupational Safety and Health Act of
1970: The employer
did not furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were potentially exposed to hazardous atmospheres while working
in a confined
space:
a)  Manhole on North River Causeway - Two employees were exposed to an
oxygen deficient
atmosphere containing hydrogen sulfide when they entered a concrete
manhole which provided
access to the sewer line.  Atmospheric testing was not performed prior to
entry.
Among other methods, feasible and acceptable means to correct this hazard
is to follow the
American National Standard Institue (ANSI), Standard Z117.1-1995,
Requirements for Confined
Spaces, including the identification of hazards within a confined space
(required in Section 3),
control or elimination of atmospheric hazards prior to entry into the
space (required in Section
5), atmospheric testing when necessary (required in Section 6), retrieval
equipment (required in
Section 12), and emergency rescue provisions (required in Section 14).

1926.21 B06 I

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Oct 21, 2008
Abate by
Oct 31, 2008
Penalty
Initial $2,500
Recent events (2)
  • — I (S)
  • — Z (S) $2500.00

1910.1200 H01

Deleted Serious Gravity 03 1 instance 3 exposed
Issued
Oct 21, 2008
Abate by
Oct 29, 2008
Penalty
Initial $1,250
Recent events (2)
  • — I (S)
  • — Z (S) $1250.00

1904.29 B01

Other-than-serious Gravity 00 2 instances 2 exposed
Issued
Oct 21, 2008
Abate by
Oct 29, 2008

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 310989355.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.